The minimum space between two hinged or pivoted doors in series shall be 48 in (1220 mm) plus the width of any door swinging into the space....
Search Results "Self-Closing Door"
-
4.13.7 TWO DOORS IN SERIES
-
R218 Doors, Doorways, and Gates
R218 Doors, Doorways, and Gates. Where provided at pedestrian facilities, doors, doorways, and gates shall comply with section 404 of Appendix D to 36 CFR part 1191....
-
2.2.6 Door Use
Door type Door 1 Door 2 Door 3 Clear opening 825 mm 1040 mm 755 mm Closer No No Yes Resistance...
-
408.3.2 Swinging Doors
408.3.2 Swinging Doors. Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
§35.105 Self-evaluation
All public entities are required to do a self-evaluation....
- DORMA ED700 Low-Energy Swing Door Operator
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
§104.6 Remedial action, voluntary action, and self-evaluation.
[45 FR 30936, May 9, 1980, as amended at 65 FR 68054, Nov. 13, 2000]
-
Door and Gate Surfaces [§404.2.10]
Door and Gate Surfaces [§404.2.10] The bottom surface of doors and gates on the push side must be smooth to a height of at least 10”....
-
Doors and Gates Operated Only By Security Personnel [§404.1, Ex]
Doors and Gates Operated Only By Security Personnel [§404.1, Ex] Manual doors, doorways, and gates that are designed to be operated only by security personnel, such as guards in...
-
Common Problems with Entrances and Doors
Common Problems with Entrances and Doors Ø Each leaf of a set of double doors is often too narrow to be used independently by someone who uses a wheelchair....
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
904.5.1 Self-Service Shelves and Dispensing Devices
Self-service shelves and dispensing devices for tableware, dishware, condiments, food and beverages shall comply with 308....
-
904.5.1 Self-Service Shelves and Dispensing Devices
Self-service shelves and dispensing devices for tableware, dishware, condiments, food and beverages shall comply with 308....
-
§35.105 Self-evaluation
§35.105 Self-evaluation....
-
Self-Evaluation Forms
These forms will take you through the process of conducting a self-evaluation and developing a transition plan and an action plan....
-
413.1.1 Caption Controls (Section-by-Section Analysis)
Section-by-Section Analysis) This proposed section would require that, where video-capable hardware provides physical volume adjustment controls, such ICT must also have a control for closed...
-
Doors [4.13]
[See subsections ...]
-
5. BENEFITS DISCUSSION
For example, some people’s hearing or vision disability may not be such that they would need closed movie captioning or audio description. ...
-
1132A.2 Interior doors and secondary exterior doors
1132A.2 Interior doors and secondary exterior doors....
-
H. Stall Door
If the accessible toilet is in a stall, is the stall door positioned diagonally opposite, not directly in front of, the toilet so persons who use wheelchairs may pull fully into the stall...