Currently, captioning is delivered to patrons in one of two formats: “open” and “closed.”...
Search Results "Self-Closing Door"
Commonly Searched Documents
-
C. Availability of Captioning and Audio Description
-
Must elevator doors remain open for 20 seconds?
LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum....
-
2.2. Total Costs
reflects “what the world will be like if the proposed rule is not adopted.”8 In the case of this rule, the no action baseline should reflect the extent to which movie theaters would provide closed...
-
Door Pressure Gauge
Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, measures forces from 0-35 pounds on one side and 0-16 kilograms on the other....
-
4.13.6 Maneuvering Clearances at Doors
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
-
Captioning at movie theaters. (Section-by-Section Analysis)
Congress was silent, however, on the question of closed captioning in movie theaters, a technology not yet developed at that time for first run movies, while acknowledging that closed captions...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-224.1.2 Guest room doors and doorways
11B-404.2.3 _|Doors, Doorways, and Gates; Clear Width|_....
-
11B-224.1.2 Guest room doors and doorways
11B-404.2.3 _|Doors, Doorways, and Gates; Clear Width|_....
-
Usable Door
One commenter stated that a clear definition of "usable door" is required. Response....
-
11B-224.1.2 Guest room doors and doorways
Bathrooms doors shall be either sliding or hung to swing in the direction of egress from the bathroom. [2010 ADA Standards] 224.1.2 Guest Room Doors and Doorways....
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
Break Out Opening: ADA Standard Section 404.3.6
Section 404.3.6 covers the current ADA Standards for the break out openings at swinging or sliding doors and gates.
-
3.3.1. Captioning Hardware Scoping Requirements
On average, a Megaplex movie theater would require 18 units of captioning hardware to provide closed movie captioning in each of the 18 auditoriums. ...
-
§ 38.25(c) Door height
(c) Door height....
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
1132A.1 Primary entry doors and required exit doors
1132A.1 Primary entry doors and required exit doors. The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
225 and 811 Storage
Self-service shelving is required to be on an accessible route, but is not required to comply with the reach range requirements....
-
NABCO GT300-02L Center Pivot Outswing LH
Requires the Premium User plan or above. (Login or upgrade your account!)
-
NABCO GT300-04 Center Pivot Simultaneous Pair Outswing
Requires the Premium User plan or above. (Login or upgrade your account!)
-
NABCO GT300-01L Center Pivot Inswing RH Single With Panic
Requires the Premium User plan or above. (Login or upgrade your account!)
-
NABCO GT300-02R Center Pivot Outswing RH
Requires the Premium User plan or above. (Login or upgrade your account!)