Table 1 and Figure 1 show the percentiles and maximum observed values for male and female wheelchair users....
Search Results "Maximum Dimension"
-
1. Abdomen depth (AD)
-
10.2.1(3)
In addition, to the maximum extent practicable, all new bus route identification signs shall comply with 4.30.2 and 4.30.3....
- Eco Grip Flooring 2min HD
-
Gratings [4.5.4]
ADAAG requires a maximum opening dimension of ½ inch in one direction and that elongated openings be placed so that the long dimension is perpendicular to the dominant direction of travel...
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Advisory 11B-302.3 Openings....
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Advisory 11B-302.3 Openings....
- Figure 408.4.1(a) Limited-Use/Limited-Application (LULA) Elevator Car Dimensions – Drawing from the U.S. Access Board
-
When an addition increases the number of stories or square footage beyond the maximum permitted by the exception, is an accessible route between stories required?
In this case, compliance is required to the maximum extent feasible....
-
Conclusions
Conclusions Design criteria based on the univariate analysis of abdomen depth is sufficient if all other clearance dimensions are unbounded (i.e., unrestricted) and abdomen depth is the...
-
Platform Size and Surface
The minimum dimensions are based on the approach. Where entry and exit are on the narrow dimension, the space must be at least 36 inches wide and at least 48 inches long....
-
1.1.7 Measurement of parking areas
These areas should be considered as a pedestrian walk with a minimum width of 60 in. and a length of approximately 20 ft and with an ADA/ABA - AG maximum slope of 1:48 in both directions...
-
407.12.3.1 Unobstructed Forward Reach (Section-by-Section Analysis)
Unobstructed Forward Reach (Section-by-Section Analysis) This section proposes that, where an unobstructed forward reach is provided, the operable part must be located 48 inches high maximum...
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
R402.3 Post-Mounted Objects
Where objects are mounted on free-standing posts or pylons and the objects are 685 mm (2.25 ft) minimum and 2030 mm (6.7 ft) maximum above the finish surface, the objects shall overhang...
-
Dimensional Tolerances [3.2]
Recommendation: It is good practice to avoid specifying precisely to the maximum or minimum where possible so that achieved dimensions fall within ADAAG requirements....
-
604.2 Location
mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in 604.8.2....
-
Grab Bar Cross Sections
Non-circular cross sections were to have maximum cross section dimensions of 2 inches, a perimeter dimension between 4 and 4‒11/16 inches, and edges with a c inch minimum radius....
-
2.2 Key Measurement Variables and Procedures
Body and wheelchair dimensions: Approximately 125 locations of body and wheelchair points recorded in three dimensions. 3....
- Figure 408.4.1(c) Limited-Use/Limited-Application (LULA) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 408.4.1(b) Limited-Use/Limited-Application (LULA) Elevator Car Dimensions – Drawing from the U.S. Access Board
-
M301.3 Transfer Supports
Circular cross sections – Circular cross sections must have an outside diameter of 1¼ inches minimum and 2 inches maximum....
-
T302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. EXCEPTIONS: 1....
-
Standing Supports (M304.3 and M305.3)
The bottom of the support would be required to be 34 inches minimum and 37 inches maximum above the standing surface....