This design guideline addresses planning and design of a building and site, including all features used to access the building or facility, such as walkways and pathways, stairs, and ramps...
Search Results "Accessible Element"
Commonly Searched Documents
- Design Guidelines for the Visual Environment
-
Outdoor Recreation Access Routes in Viewing Areas [F246.4]
At viewing areas not located along trails, at least one ORAR must connect accessible parking spaces or other arrival points that serve the viewing area with accessible elements, spaces,...
-
A. Accessible Voting Program
Harris County shall provide accessible polling places in order to have an accessible voting program, including a program that is accessible to persons with mobility or vision disabilities...
-
§ 37.3 Accessible
Accessible means, with respect to vehicles and facilities, complying with the accessibility requirements of parts 37 and 38 of this title....
-
4.23.8 Bathing and Shower Facilities
If tubs or showers are provided, then at least one accessible tub that complies with 4.20 or at least one accessible shower that complies with 4.21 shall be provided.....
-
4.23.8 BATHING AND SHOWER FACILITIES
If tubs or showers are provided, then at least one accessible tub that complies with 4.20 or at least one accessible shower that complies with 4.21 shall be provided....
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm)...
-
Title II: Program Accessibility
NOTE: Public entities must comply with either the 1991 Standards, UFAS, or the 2010 Standards for all elements within a single building....
-
Floor or Ground Surfaces: ADA Standard Section 502.4
Section 502.4 covers the current ADA Standards for the floor or ground surfaces of accessible parking spaces.
-
Direct Connections: ADA Standard Section 206.4.4.2
Section 206.4.4.2 covers scoping requirements in the most current ADA Standards for accessible routes to direct connections at transportation facilities.
- American Standard Ovalyn™ Universal Access Undercounter Sink
-
Fishing Piers and Platforms: ADA Standard Section 206.2.14
Section 206.2.14 covers scoping requirements in the most current ADA Standards for accessible routes to fishing piers and platforms.
-
Vehicle Spaces: ADA Standard Section 502.2
Section 502.2 covers the current ADA Standards for vehicle spaces.
- Figure 703.7.2.2 International Symbol of TTY – Drawing from the U.S. Access Board
- Figure 703.7.2.3 Volume Control Telephone – Drawing from the U.S. Access Board
-
Incidental Spaces: ADA Standard Section 206.7.3
Section 206.7.3 covers scoping requirements in the most current ADA Standards for accessible routes to incidental spaces.
-
502.3 Access Aisle
Access aisles serving parking spaces shall comply with 502.3. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle....
-
502.3 Access Aisle
Access aisles serving parking spaces shall comply with 502.3. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle....
-
402 Accessible Routes
Section 402 lists the various elements that can be part of an accessible route: walking surfaces, doorways, ramps, elevators, and platform lifts....
-
Parallel Approach to Kitchen Sinks
Comment. Commenters recommended that a parallel approach should be allowed at kitchen sinks in spaces without a cook top or conventional range, consistent with the ANSI A117.1...
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall. Figure 608.3.1 Grab Bars...
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall.
-
2. Roll-in Shower Size
2. If there are more than 50 guestrooms/suites, are all required roll-in showers at least 30" wide by 60" long or 36" wide by 60", as configured in Figure 57 below, so persons who...