Section508.gov opening doors logo....
Search Results "Door Surface"
Commonly Searched Documents
-
Section 508
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
11B-405.8 Handrails
At door landings, handrails are not required on ramp runs less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-206.4 Entrances
Entrance doors, doorways, and gates shall comply with Section 11B-404 and shall be on an accessible route complying with Section 11B-402. Exceptions: 1. Reserved....
-
11B-604.3.1 Size
Note The CBC 11B-604.3.1 requirement for maneuvering space in front of accessible water closets exceeds the 2010 ADA Standards requirement for water closet clear floor space, but a door...
-
1.3 Previous Research
Most of the studies reviewed do not adequately report on the lighting conditions and color and luminance contrast between detectable warning surfaces and surrounding surfaces....
-
1.2 Background
Detectable warning surfaces are intended primarily to provide a tactile cue to pedestrians who are blind or have visual impairments....
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor or ground surface...
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor or ground surface...
-
Animal Containment Areas
These areas must comply with all ADAAG requirements, except the requirements that surfaces be stable, firm, and slip resistant and the restrictions on changes in level since some surfaces...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Comments from Individuals Who Are Blind or Have Low Vision (Section-by-Section Analysis)
Analysis) The National Federation of the Blind was a member of the advisory committee that recommended the proposed guidelines, but filed a minority report recommending detectable warning surfaces...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Folding Seats on Equipment Used by Patients Seated in a Wheelchair (M302.4 Exception)
However, the folding seat would be required to meet the other technical criteria in M302 for transfer surfaces and supports. Question 28....
-
11B-405.9.2 Curb or barrier
, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground surface...
-
11B-405.9.2 Curb or barrier
or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground surface...
-
CURB CUT
An interruption of a curb at a pedestrian way, which separates surfaces that are substantially at the same elevation....
-
11B-705.1.1 General
Detectable warnings shall consist of a surface of truncated domes and shall comply with Section 11B-705....
-
GRADE BREAK
[DSA-AC] The line where two surface planes with different slopes meet....
-
903.7 Wet Locations
Where installed in wet locations, the surface of the seat shall be slip resistant and shall not accumulate water....
-
11B-903.7 Wet locations
Where installed in wet locations, the surface of the seat shall be slip resistant and shall not accumulate water....
-
903.7 Wet Locations
Where installed in wet locations, the surface of the seat shall be slip resistant and shall not accumulate water....
-
705.1 General
Detectable warnings shall consist of a surface of truncated domes and shall comply with 705....
-
TRANSITION PLATE
[DSA-AC] A sloping pedestrian walking surface located at the end(s) of a gangway....