Additional space for maneuvering and a wider door will be needed where a side opening is centered on the ride....
Search Results "Door Surface"
-
11B-1002.4.4.2 Side entry
-
Entrances: ADA Standard Section 206.4
Section 206.4 covers scoping requirements in the most current ADA Standards for entrances on accessible routes.
- Hadrian Inc. Corridor Lockers
-
Transfer Steps: ADA Standard Section 1009.5.4
The surface of the bottom tread shall extend to a water depth of 18 inches (455 mm) minimum below the stationary water level. Advisory 1009.5.4 Transfer Steps....
-
Height: ADA Standard Section 1005.2.1
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
Clear Width: ADA Standard Section 403.5.1
Section 403.5.1 covers the current ADA Standards for the clear width of walking surfaces that are part of an accessible route.
-
§382.63(a)(3)
(3) The lavatory shall provide door locks, accessible call buttons, grab bars, faucets and other controls, and dispensers usable by qualified individuals with a disability, including wheelchair...
-
Head Room [4.3.5]
Eighty-inch doors, including those equipped with closers, are considered acceptable under this requirement....
-
Elevator Car Requirements [§407.4]
Alternative configurations that provide unobstructed wheelchair turning space (60” diameter circle or T-turn) with the doors closed are permitted....
-
§ 38.119(a)
(a) Any stepwell, or doorway with a lift, ramp or bridge plate, shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread, ramp, bridge plate...
-
§ 38.81(a)
(a) Any stepwell or doorway with a lift, ramp or bridge plate immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the...
-
11B-406.5.6 Grade breaks
Grade breaks shall not be permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks shall be flush....
-
Story
That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
-
11B-406.5.6 Grade breaks
Grade breaks shall not be permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks shall be flush....
-
11B-406.5.6 Grade breaks
Grade breaks shall not be permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks shall be flush....
-
106.5.64 Story
That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
-
Visual Alarms
Result: People who are deaf or hard of hearing cannot hear fire alarms, ringing telephones, knocking at doors or ringing doorbells....
-
DEFENDANTS’ RAISED PORCHES
At each of the 249 stores in question, two public entrances with doors that are not part of the porch flank the raised porch. ...
- AJW Architectural Products U592 1.6 Gallon Sanitary Napkin Disposal w/ Keyed Access Panel & Mounted Shelf - Surface Mounted
-
A. Accessible Voting Program
facilities and equipment (including, but not limited to, permanent equipment such as lifts and elevators, and temporary equipment such as portable ramps, traffic cones, signs, wedges, and door...
-
11B-604.3.2 Overlap
When the door to the toilet room is placed directly in front of the water closet, the water closet cannot overlap the required maneuvering clearance for the door inside the room. ◼ ...
-
11B-604.3.2 Overlap
When the door to the toilet room is placed directly in front of the water closet, the water closet cannot overlap the required maneuvering clearance for the door inside the room. ◼ ...
-
Test Procedures
Accessibility and Durability Measures The beach path surfaces were periodically measured with a rotational penetrometer....
-
Klingstone 400
) and a very small amount of loose fines coming to the surface....