(1) The sink and surrounding counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable...
Search Results "Door Surface"
Commonly Searched Documents
-
4.34.6.5(1)
-
11B-705.3 Product Approval
Only approved DSA-AC detectable warning products and directional surfaces shall be installed as provided in the California Code of Regulations (CCR), Title 24, Part 1, Chapter 5, Articles...
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
DETECTABLE WARNING
A standardized surface feature built in or applied to walking surfaces or other elements to warn persons with visual impairments of hazards on a circulation path....
-
1134A.2 Number of complying bathrooms
If a door is provided, it shall comply with the requirements of Section 1132A.5. 8. ...
-
1134A.2 Number of complying bathrooms
If a door is provided, it shall comply with the requirements of Section 1132A.5. 8....
-
11B-504.8 Floor identification
Sections 11B-703.1, 11B-703.2 _|Raised Characters|_, 11B-703.3 _|Braille|_ and 11B-703.5 _|Visual Characters|_ shall be located at the landing of each floor level, placed adjacent to the door...
-
III-6.4000 Alterations: Historic preservation
There appears, however, to be a problem if one of the interior doors is widened, because historic decorative features on the door might be destroyed....
-
11B-504.8 Floor identification
Sections 11B-703.1, 11B-703.2 _|Raised Characters|_, 11B-703.3 _|Braille|_ and 11B-703.5 _|Visual Characters|_ shall be located at the landing of each floor level, placed adjacent to the door...
-
1023.9 Stairway identification signs
characters and braille floor identification signs that comply with Chapter 11A, Section 1143A or Chapter 11B shall be located at the landing of each floor level, placed adjacent to the door...
-
Number of Accessible Telephones
Similarly, if a narrow door is replaced, the doorway need not be widened as a consequence of the door replacement....
- Spectrum Industries Inc. Freedom One Sit-to-Stand Lectern
-
New Construction and Alterations
If you build a new facility or modify your existing one, (for example, work such as restriping the parking area, replacing the entry door or renovating the sales counter), make sure to consult...
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
K. Ambulatory Stall
than 5 stalls in any restroom, is there one stall in addition to the large accessible stall, that is 36" wide, has 2 parallel grab bars at 33"-36" off the floor and has an out-swinging door...
-
Sec.36.304(c)(2)
These measures include, for example, adjusting the layout of display racks, rearranging tables, providing Brailled and raised character signage, widening doors, providing visual alarms,...
-
§ 36.304(c)(2)
These measures include, for example, adjusting the layout of display racks, rearranging tables, providing Brailled and raised character signage, widening doors, providing visual alarms,...
-
Operable Parts Covered [§205]
Operable parts include light switches, electrical and communication receptacles, thermostats, alarm pulls, automatic door controls, and other elements used by facility occupants....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
801.1 Scope
For example, 806 addresses guest rooms in transient lodging facilities while 902 contains the technical specifications for dining surfaces....
-
801.1 Scope
For example, 806 addresses guest rooms in transient lodging facilities while 902 contains the technical specifications for dining surfaces....
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
903.4 Back Support
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
M302.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...