Additions and alterations to existing buildings or facilities shall comply with 202....
Search Results "Fire-Building Surface"
-
202.1 General
-
Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
Evaluate Your Need to Identify as Someone Who Requires Assistance During an Evacuation
(FEMA & United States Fire Administration 2001) Many do not recognize their own need for assistance....
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
R305.1 General
Detectable warning surfaces shall consist of truncated domes aligned in a square or radial grid pattern and shall comply with R305....
-
4.9.4(5)
(5) Top of handrail gripping surface shall be mounted between 34 in and 38 in (865 mm and 965 mm) above stair nosings....
-
4.15.2* Spout Height
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a))....
-
4.19.6* MIRRORS
Mirrors shall be mounted with the bottom edge of the reflecting surface no higher than 40 in (1015 mm) from the floor (see Fig. 31)....
-
1005.3.1 Curb or Barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
11B-1007.2 Accessible routes
Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in Section 11B-1007.2....
-
1007.2 Accessible Routes
Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in 1007.2. EXCEPTIONS: 1....
-
Additional Transfer Techniques: Use of Stretchers and Gurneys
feasible or possible to use a lift, another option is an adjustable-height stretcher or gurney (a table that is on wheels) that can be raised or lowered to the height of the exam table or surface...
-
R402 Protruding Objects (Section-by-Section Analysis)
R402 Protruding Objects (Section-by-Section Analysis) Objects with leading edges between 685 millimeters (2.25 feet) and 2 meters (6.7 feet) above the finish surface must not protrude...
-
1016.4 Passing Spaces
the route is heavily used or adjoins elements, spaces, or facilities that are heavily used; or where the route is a boardwalk or otherwise not at the same level as the adjoining ground surface...
-
"Direct Threat" to Self
Nor could an employer reject an applicant with a visual or mobility disability because of a generalized fear of risks to this person in the event of a fire or other emergency....
-
809.3.1.2 Residential Dwelling Unit Smoke Alarms
This requirement is consistent with the NFPA 72 National Fire Alarm Code, which is referenced in the section....
-
Emergency Planning
If the facility does not have evacuation elevators, does it have areas of refuge (fire-rated spaces where people who cannot use stairs can go to register a call for help and wait for responders...
-
Conventions Used In This Guide
Number Hyperlink] Used for Safe Harbor hyperlinks [F] Used to indicate sections that are adopted by the CBC and also in the California Fire...
-
§ 36.406(a)(1)
(1) New construction and alterations subject to §§ 36.401 or 36.402 shall comply with the 1991 Standards if the date when the last application for a building permit or permit extension is...
-
UNREASONABLE HARDSHIP
When the enforcing agency finds that compliance with the building standard would make the specific work of the project affected by the building standard infeasible, based on an overall evaluation...
-
§ 36.406(a)(3)
(3) New construction and alterations subject to §§ 36.401 or 36.402 shall comply with the 2010 Standards if the date when the last application for a building permit or permit extension is...
-
[A] 101.2 Scope
this code shall apply to the construction, alteration, relocation, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every building...
-
101.2 Scope
this code shall apply to the construction, alteration, relocation, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every building...
-
UNREASONABLE HARDSHIP
When the enforcing agency finds that compliance with the building standard would make the specific work of the project affected by the building standard infeasible, based on an overall evaluation...