Van Accessible Parking Spaces. The 1991 Standards, at sections 4.1.2 (5)(b), 4.6.3, 4.6.4, and 4.6.5, require one in every eight accessible parking spaces to be van accessible....
Search Results "Water Closet Clear Floor Space"
-
Van Accessible Parking Spaces
-
Birthing Room Bath Tub Accessibility
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 11B-603 (Toilet and Bathing Rooms) through 11B-610 (Seats)....
-
1010.1 Turning Space
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
1010.1 Turning Space
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
R214 On-Street Parking Spaces
R214 On-Street Parking Spaces....
-
11B-703.4.1 Height above finish floor or ground
mm) maximum above the finish floor or ground surface, measured from the baseline of the highest line of raised characters...
-
2. Adequate Space
Within the voting area, is adequate space available on the accessible level for check-in tables, a voting demonstration area (if provided), and at least one accessible voting station?...
-
1004 Exercise Machines
This section requires clear floor space for transfer to, or use of, exercise machines....
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
Flush Controls [4.16.5]
Flush Controls [4.16.5] Flush valve controls must be mounted no more than 44 inches above the floor on the wide side of the toilet so that they are within reach from the available clear...
-
Knee and Toe Space
The knee and toe space must be at least as deep as the reach depth measured from the leading edge of the obstruction....
-
11B-806.2 Guest rooms with mobility features
The requirements in Section 11B-806.2 do not include requirements that are common to all accessible spaces....
-
11B-806.2 Guest rooms with mobility features
The requirements in Section 11B-806.2 do not include requirements that are common to all accessible spaces....
-
11B-703.4.1 Height above finish floor or ground
mm) maximum above the finish floor or ground surface, measured from the baseline of the highest line of raised characters...
-
Chapter 4: Implications for standards and design
[See subsections ...]
-
4.1.6(3)(f)(i)
(i) Where it is technically infeasible to disperse accessible seating throughout an altered assembly area, accessible seating areas may be clustered. Each accessible seating area...
-
4.1.6(4)(f)
(f) Assembly areas. (i) In alterations where it is structurally impracticable to disperse seating throughout the assembly area, seating may be located in collected areas as...
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...
-
F. Parking Space Location
If there is more than one accessible parking space, are the accessible parking spaces the closest parking spaces to the lobby entrance and accessible guestroom entrance(s)?...
-
Elevator Operable Parts
The proposed rule specified that call buttons be located 35 to 48 inches above the floor (407.2.2)....
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
Height and Clearances [4.19.2]
Only a portion of the usable clear floor space can "count" as toe space, which is why a maximum depth and minimum height are specified for the front of the underlap of the required clear...