(3) Wheelchair spaces and companion seats are not located on (or obstructed by) temporary platforms or other movable structures, except that when an entire seating section is placed on temporary...
Search Results "Water Closet Clear Floor Space"
-
§ 35.151(g)(3)
-
Can a single EV charger service two EV Accessible spots or does each spot have to have its own charger?
RESPONSE: A single multiport EV charger that can simultaneously charge two vehicles can be used to serve two EV spaces required to be accessible....
- Elkay Filtered EZH2O® Bottle Filling Station with Single ADA Cooler LZS8WSVRSK
-
206.7.5 Existing Site Constraints
For example, a new building constructed between and connected to two existing buildings may have insufficient space to coordinate floor levels and also to provide ramped entry from the public...
-
11B-233.3.1.2.4 Multi-story residential dwelling units
facilities with multi-story residential dwelling units shall comply with the following: Exception: In non-elevator buildings, a minimum of 10 percent but not less than one of the ground floor...
-
1016.1 General
The technical requirements address the surface of outdoor recreation access routes, passing spaces, and resting intervals (1016.2); the clear width of outdoor recreation access routes (1016.3...
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4....
-
M303.2.3.1 Front or Rear Entry
Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum....
- Access-Able Designs Shower Transfer Bench SH-420-2SDL
-
M303.2.4.1 Toe Clearance
Toe clearance shall be provided at a height of 9 inches (230 mm) above the floor to a depth of 6 inches (150 mm) maximum....
-
F246.4 Outdoor Recreation Access Routes
At least one outdoor recreation access route complying with 1016 shall connect accessible parking spaces or other arrival points serving the viewing area with accessible elements, spaces...
-
806 Transient Lodging Guest Rooms
Substantive changes made to this section revise requirements for: vanity counter spaces in accessible toilet or bathing rooms (806.2.4.1) wheelchair turning space (806.2.6...
-
11B-812.7 Access aisle
Two vehicle spaces shall be permitted to share a common access aisle....
-
1003.2.1 Boat Slips
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7....
-
1003.2.1 Boat Slips
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7....
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated assemblies (doors, walls, ceilings, and floors...
-
11B-903.7 Wet locations
Where installed in wet locations, the surface of the seat shall be slip resistant and shall not accumulate water....
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum....
-
502.3 Access Aisle
Access aisles serving parking spaces shall comply with 502.3. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle....
- Hussey Seating Company Roll-A-Way Seating
-
106.5.16 Catch Pool
A pool or designated section of a pool used as a terminus for water slide flumes....
-
Signage