Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface.
Search Results "Table"
Commonly Searched Documents
-
M305.2.1.2 Side Transfer Supports
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side.
-
M305.2.2.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer...
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position. A 3-inch maximum obstruction is permitted at transfer...
-
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. Transfer supports should be positioned 6 inches minimum and 19 inches maximum...
-
5.4.3 Transfer Support Height for M301 and M302
5.4.3 Transfer Support Height for M301 and M302 Description: Transfer support height applies to the vertical distance that the gripping area of the support is above the transfer...
- Midmark 641 Barrier-Free® Power Procedures Chair
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8...
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25...
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302 Description: Transfer side provisions are the same for M301 and M302 and require the transfer surface to be...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The gripping surfaces of the transfer support must be free of...
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height
-
5.1.2 Transfer Surface High Height
5.1.2 Transfer Surface High Height. The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches.
-
5.1.1 Transfer Surface Height Adjustability
5.1.1 Transfer Surface Height Adjustability. The transfer surface should have an adjustable height in small virtually continuous increments.
-
804.3 Kitchen Work Surface (Exception)
The exception does not require work surfaces to be provided at kitchen counters where a table is provided within the kitchen; an electric outlet is provided within reach of the table; and...
-
5 “G’s” Getting Access to Health Care for People with Physical Disabilities
By June Isaacson Kailes, Associate Director Center for Disability Issues and the Health Professions Western University of Health Sciences jik@pacbell.net 2008...
-
Accessible Medical Equipment
For participants with mobility limitations, we use exam and procedural tables and chairs that: [See Resources below and Section H] D.1....
- Kompan, Inc. ELE400205 - Cottage Playhouse
-
5.1 Transfer Surface Height
5.1 Transfer Surface Height
-
5.1.4 Transfer Surface Height Measurement
5.1.4 Transfer Surface Height Measurement. The transfer surface height should be measured from the floor to the highest point on the seat in an uncompressed state, inclusive of...
- Defining and Delivering Disability-Competent Care - The Lived Experience Of Disability
-
California Department of Managed Health Care - Physical Access to Health Care Fact Sheet
If You Use a Wheelchair or Have a Hard Time Walking
-
M302.2.2 Sunset