M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
Spas: ADA Standard Section 242.4
Section 242.4 covers scoping requirements in the current ADA Standards for spas.
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
- Harmar CPL800H-1400H Hydraulic CPL with Modular Tower
- Patriot Portable Lift by Aqua Creek Products
- Garaventa Xpress II Inclined Platform Wheelchair Lift Operation Video
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
The horizontal distance from transfer surface should be no more than 3 inches from the edge of the patient support surface....
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
The transfer surface should be located such that the long dimension of 28 inches is located parallel to the patient scanning/imaging side of the table....
-
Section 37.165 Lift and Securement Use
Section 37.165 Lift and Securement Use This provision applies to both public and private entities....
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
M304.1 General
Diagnostic equipment used by patients in a standing position shall comply with M304....
-
M301.3.1 Transfer Supports
patient monitoring, etc....
-
Door Maneuvering Clearance
This exception derives from the original ADAAG and was intended to apply to those types of patient rooms where patients are typically transported in and out by hospital staff....
-
5.9 Standing Support for Equipment Used by Patients in a Standing Position
5.9 Standing Support for Equipment Used by Patients in a Standing Position....
-
15. Can I store my lift and bring it out only when it is requested by a person with a disability?
Can I store my lift and bring it out only when it is requested by a person with a disability? No....
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
OTHER QUESTIONS
[See subsections ...]
-
§ 38.23(b)(2) Controls
(2) Controls—
-
§ 38.23(b)(4) Power or equipment failure
(4) Power or equipment failure. Platforms stowed in a vertical position, and deployed platforms when occupied, shall have provisions to prevent their deploying, falling, or folding...
-
F223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient or resident sleeping rooms shall be provided in accordance...
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...