No part of the platform shall move at a rate exceeding 6 inches/second during lowering and lifting an occupant, and shall not exceed 12 inches/second during deploying or stowing....
Search Results "Patient Lift"
Commonly Searched Documents
-
§ 38.83(b)(10) Platform movement
-
5.2.2 Transfer Surface Size for Equipment Used by Patients in Seated Position
5.2.2 Transfer Surface Size for Equipment Used by Patients in Seated Position....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
General: ADA Standard Section 1009.1
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
Wheelchair Spaces: ADA Standard Section 206.7.2
Section 206.7.2 covers scoping requirements in the most current ADA Standards for accessible routes to wheelchair spaces.
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
-
6a.
Is the lift operational at the time of the survey? Yes _____ No _____...
-
11B-206.7.2 Wheelchair spaces
Platform lifts shall be permitted to provide an accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of Sections 11B-221 and 11B-802....
-
410.2 Floor Surfaces
Floor surfaces in platform lifts shall comply with 302 and 303....
-
410.2 Floor Surfaces
Floor surfaces in platform lifts shall comply with 302 and 303....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
E1-f
If a wheelchair lift is provided, does it meet the following? Yes No...
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
f-i
Is the lift operational at the time of the survey? [ADA Standards § 4.11.3] Yes No...
-
6b.
Is the change in level from the floor to the lift surface ramped or beveled? Yes _____ No _____...
-
410.2 Floor Surfaces
Floor surfaces in platform lifts shall comply with 302 and 303....
-
11B-410.2 Floor surfaces
Floor surfaces in platform lifts shall comply with Sections 11B-302 and 11B-303....
-
11B-410.2 Floor surfaces
Floor surfaces in platform lifts shall comply with Sections 11B-302 and 11B-303....
-
11B-410.2 Floor surfaces
Floor surfaces in platform lifts shall comply with Sections 11B-302 and 11B-303....
-
§ 38.83(b)(11) Boarding direction
The lift shall permit both inboard and outboard facing of wheelchairs and mobility aids....
-
§ 38.23(b)(11) Boarding direction
The lift shall permit both inboard and outboard facing of wheelchair and mobility aid users....
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
The horizontal distance from transfer surface should be no more than 3 inches from the edge of the patient support surface....