Floor surfaces in platform lifts shall comply with 302 and 303....
Search Results "Patient Lift"
-
410.2 Floor Surfaces
-
§ 38.83(b)(11) Boarding direction
The lift shall permit both inboard and outboard facing of wheelchairs and mobility aids....
-
§ 38.23(b)(11) Boarding direction
The lift shall permit both inboard and outboard facing of wheelchair and mobility aid users....
-
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface on which patients are in the...
-
General
General Because many patients in a medical care facility may experience reduced mobility during their stay, at least 10% of patient bedrooms and in-room bathrooms must be fully accessible...
- Harmar CPL800H-1400H Hydraulic CPL with Modular Tower
-
Clear Deck Space
Clear Deck Space Clear deck space must be provided to enable a person to get close enough to the pool lift seat to easily transfer from a wheelchair or mobility device....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
M304.1 General (Section-by-Section Analysis)
This is an introductory section.
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-223.1.1 Alterations
Where patient bedrooms or resident sleeping rooms are altered or added, the requirements of Section 11B-223 shall apply only to the patient bedrooms or resident sleeping rooms being altered...
-
11B-223.1.1 Alterations
Where patient bedrooms or resident sleeping rooms are altered or added, the requirements of Section 11B-223 shall apply only to the patient bedrooms or resident sleeping rooms being altered...
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303....
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303....
-
11B-223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...
-
1009.2.6 Footrests and Armrests
EXCEPTION: Footrests shall not be required on pool lifts provided in spas....
-
1009.2.6 Footrests and Armrests
EXCEPTION: Footrests shall not be required on pool lifts provided in spas....
-
1009.2.6 Footrests and Armrests
EXCEPTION: Footrests shall not be required on pool lifts provided in spas....
-
M305.2.3 Fittings
M305.2.3 Fittings Proposed requirement: Transfer supports shall not rotate within their fittings • Sub-Committee Recommendation: Transfer supports shall not rotate within...
-
§ 38.83(b)(4) Power or equipment failure
Lift platforms stowed in a vertical position, and deployed platforms when occupied, shall have provisions to prevent their deploying, falling, or folding any faster than 12 inches/second...
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
Platform to Runway Clearance: ADA Standard Section 410.4
Section 410.4 covers the current ADA Standards for the required clearance between the platform and any runway landing.
-
11B-410.4 Platform to runway clearance
The clearance between the platform sill and the edge of any runway landing shall be 1¼ inch (32 mm) maximum.