[See subsections ...]
Search Results "Forward Approach"
-
2. c. i. Forward reach
-
11B-404.3.5 Controls
A level and clear floor or ground space for forward or parallel approach complying with Section 11B-305 should be provided, centered on the operating device....
-
11B-404.3.5 Controls
A level and clear floor or ground space for forward or parallel approach complying with Section 11B-305 should be provided, centered on the operating device....
-
12. Reach Range
Are there towel racks or bars placed within 54" of the floor for side approach or 48" of the floor for forward approach so persons who use wheelchairs can approach and use the towel racks...
-
5. Clear floor space
Clear floor space is needed for a forward approach to the lavatory....
-
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)]
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)] Clear floor space for either a forward or a side approach is permitted for cabinets, counters, sinks, and appliances....
-
M. Reach Range
Are the rod and shelf in the clothes closet or wall mounted unit within 54" of the floor for side approach or 48" of the floor for forward approach so persons who use wheelchairs can approach...
-
7(1)(c)
(c) In U-shaped kitchens with sink or range or cooktop at the base of the "U", a 60-inch turning radius is provided to allow parallel approach, or base cabinets are removable at that location...
-
L. Controls
Are all drapery control wands, fixed lamps and HVAC controls in accessible guestrooms placed within 54" of the floor for side approach or 48" of the floor for forward approach so persons...
-
211 and 602 Drinking Fountains
The 1991 Standards require wall and post-mounted cantilevered drinking fountains mounted at a height for wheelchair users to provide clear floor space for a forward approach with knee and...
-
7(1)(a)
(a) A clear floor space at least 30 inches by 48 inches that allows a parallel approach by a person in a wheelchair is provided at the range or cooktop and sink, and either a parallel or...
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
26.1 Q. Is a parallel approach required at the shower, as shown in Figure 7(d) of the Guidelines?
Thus the parallel approach as shown in Figure 7(d) is essential in order to be able to transfer from the wheelchair to the shower seat....
-
7(2)(a)
walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach...
-
Clear Floor Space [4.34.2] and Reach Ranges [4.34.3]
Clear Floor Space [4.34.2] and Reach Ranges [4.34.3] Either a forward approach or a parallel approach to the ATM must be provided....
-
DRIVE-UP ELECTRIC VEHICLE CHARGING STATION
An electric vehicle charging station in which use is limited to 30 minutes maximum and is provided at a location where the electric vehicle approaches in the forward direction, stops in...
-
DRIVE-UP ELECTRIC VEHICLE CHARGING STATION
An electric vehicle charging station in which use is limited to 30 minutes maximum and is provided at a location where the electric vehicle approaches in the forward direction, stops in...
-
Knee Clearance: Clearance as Measured from Anterior-Most Point - Manual Wheelchair
This depicts knee and toe clearance required by manual chair users for forward approach to elements in the built environment (e.g., light switches)....
-
Storage [9.2.2(4)]
Clear floor space for either a forward or side approach is allowed....
-
Attachment H
clear floor space of 30 by 48 inches that allows a forward or parallel approach by a person using a wheelchair. ...
-
4.5.2 Clear Floor or Ground Space
The space shall be positioned for either forward or side approach to the container opening and be adjacent to or overlap the ORAR....
-
1133A.2, Item 4
The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space, appliance...
-
1133A.2, Item 3
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
1133A.2, Item 3
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...