This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
Search Results "Ground Surface"
-
1007.8 Exterior area for assisted rescue
-
1003.2.13.7 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
§ 36.404(a)(2)(ii)
(ii) A series of buildings on a common site, connected by a common pedestrian access route above or below the ground floor, that is either under common ownership or common control or developed...
-
Sec.36.404(a)(2)(ii)
(ii) A series of buildings on a common site, connected by a common pedestrian access route above or below the ground floor, that is either under common ownership or common control or developed...
-
Protruding Objects [4.4]
The diagonal technique involves holding the cane in a stationary position diagonally across the body with the bottom tip at the ground beyond one shoulder and the grip extending beyond the...
-
Scoping [4.1.3(8)]
of the number of public entrances (whichever is greater); and at least one entrance to each separate tenancy is accessible at least one accessible entrance serves the ground...
-
1017.4.1 Size
Where the passing space is the intersection of two trails, the intersection must be as flat as possible so that all of the wheels of a mobility device touch the ground when turning into...
-
DOT Memorandum: INFORMATION: Snow Removal on Sidewalks Constructed with Federal Funding
For more information see section 4.3.1, Surface Repairs, Snow Removal, and Vegetation in the AASHTO Guide for the Planning, Design, and Operation of Pedestrian Facilities (July 2004)....
-
Using Patient Lifts
Then the sling is attached to the lift so the staff person can move the individual to the examination surface....
-
Elevated Accessible Routes
narrowed width permitted for 24-inch (610 mm) length to accommodate features in the composite structure 12-inch (305 mm) rise maximum per ramp run Top of handrail gripping surfaces...
-
809.2.2 Turning Space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
Technical Memorandum TM 2012-04 Multi-Story Buildings and Facilities
The term “story” is defined in 106.5.64 as that portion of a building or facility designed for human occupancy included between the upper surface of a floor or the upper surface of the floor...
-
REFERENCES
., Proposed Surface Roughness Standard for Pathways used by Wheelchairs. Transportation Research Board 93nd Annual Meeting, 2014(14-4494). 5....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position; M302 Diagnostic Equipment Used by Patients in Seated Position
Except for the size of the transfer surface (see M301.2.2 and M302.2.2) and certain supports (see M301.3.2 for stirrups, and M302.3.2 for armrests), the technical criteria in these sections...
-
§ 38.95(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
§ 38.125(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
§ 38.83(b)(13) Handrails
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
-
11B-505.10.3 Bottom extension at stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
809.2.2 Turning Space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
809.2.2 Turning Space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
11B-1009.2.2 Seat location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48. FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION...
-
R409.10.3 Bottom Extension at Stairways
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....