Within play areas, ramps connecting ground level play components and ramps connecting elevated play components shall comply with Section 11B-1008.2.5....
Search Results "Soft Contained Play Structure"
-
11B-1008.2.5 Ramps
-
BACKGROUND
BACKGROUND Section 5.4.11 of the Committee report makes the following recommendation: 5.4.11 Transfer Support Structural Strength Recommendations for M301 and M302 Description:...
-
1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
F240.2.1.1 Minimum Number and Types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with 1008.4....
-
240.2.1.1 Minimum Number and Types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with 1008.4....
-
1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
1008.4.3 Play Tables
Where play tables are provided, knee clearance 24 inches (610 mm) high minimum, 17 inches deep (430 mm) minimum, and 30 inches (760 mm) wide minimum shall be provided....
-
1008.4.3 Play Tables
Where play tables are provided, knee clearance 24 inches (610 mm) high minimum, 17 inches deep (430 mm) minimum, and 30 inches (760 mm) wide minimum shall be provided....
-
11B-240.2.1.1 Minimum number and types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with Section 11B-1008.4. ...
-
11B-240.2.1.1 Minimum number and types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with Section 11B-1008.4....
-
11B-240.2.1.1 Minimum number and types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with Section 11B-1008.4....
-
240.2.1.1 Minimum Number and Types
Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with 1008.4....
- BYO Recreation Inc. Accent Swing Seat
-
4.1.1(5)(a)
(a) In new construction, a person or entity is not required to meet fully the requirements of these guidelines where that person or entity can demonstrate that it is structurally impracticable...
-
4.1.6(3)
facility, then each element or space that is altered or added shall comply with the applicable provisions of 4.1.1 to 4.1.4 of 4.1, Minimum Requirements, except to the extent where it is structurally...
-
203.6 Single Occupant Structures
203.6 Single Occupant Structures....
-
6. Where multiple swings in a swing bay are provided, Section 240.2.1.1 (one of each type) requires one swing to be located on an accessible route. If an accessible route is provided to more than one swing, can each swing be counted as an accessible ground level play component? If one is an infant seat and another a sling seat, are those considered two different types?
If an accessible route is provided to more than one swing, can each swing be counted as an accessible ground level play component?...
-
When Transfer Systems Are Used
In play areas with 20 or more elevated play components, transfer systems may be used to connect up to 25 percent of the elevated play components and the rest of the elevated play components...
-
11B-302.1 General
Exceptions: Within animal containment areas, floor and ground surfaces shall not be required to be stable, firm, and slip resistant....
-
11B-302.1 General
Exceptions: Within animal containment areas, floor and ground surfaces shall not be required to be stable, firm, and slip resistant....
- Kompan, Inc. M593 - Water Tap
-
17. Can broken or older ground level play components be replaced without changing the surface?
Can broken or older ground level play components be replaced without changing the surface? Yes....