Where an existing ground level play component is replaced, should the new component comply with the technical provisions of Section 1008.4 even if there is not an accessible route to it?...
Search Results "Soft Contained Play Structure"
-
18. Where an existing ground level play component is replaced, should the new component comply with the technical provisions of Section 1008.4 even if there is not an accessible route to it?
-
1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with 505 except as modified by 1008.2.5.3. EXCEPTIONS: 1....
-
1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with 505 except as modified by 1008.2.5.3. EXCEPTIONS: 1....
-
H.4.ii. - If an instructor uses slides from presentation software, such as Microsoft PowerPoint or Corel Presentations, which are projected to a live class, do the Access Board standards apply?
However, if the slides contain embedded multimedia elements, such as videos, then the Access Board standards apply to this live presentation....
-
1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with 505 except as modified by 1008.2.5.3. EXCEPTIONS: 1....
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
Clear Floor or Ground Space
Each play component is unique and the spaces must be placed in the best location for the situation....
-
Elevated Accessible Routes
Elevated accessible routes must connect the entry and exit points of at least 50 percent of the elevated play components provided in the play area. ...
-
11B-1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
11B-1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
11B-1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
Kompan, Inc. Sandboxes and Water Play - M590P - Mermaid's Fountain
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Kompan, Inc. Sandboxes and Water play - M593 - Water Tap
Requires the Premium User plan or above. (Login or upgrade your account!)
- Morgan’s Inspiration Island - San Antonio, Texas
-
§ 382.57(c)(1) Self contained
(1) Self contained. Except for personal headsets and audio loops, automated kiosks must be operable without requiring the user to attach assistive technology....
-
F240.1.1 Additions
Where play areas are designed and constructed in phases, the requirements of F240 shall apply to each successive addition so that when the addition is completed, the entire play area complies...
-
240.1.1 Additions
Where play areas are designed and constructed in phases, the requirements of 240 shall apply to each successive addition so that when the addition is completed, the entire play area complies...
-
11B-240.1.1 Additions
Where play areas are designed and constructed in phases, the requirements of Section 11B-240 shall apply to each successive addition so that when the addition is completed, the entire play...
-
240.1.1 Additions
Where play areas are designed and constructed in phases, the requirements of 240 shall apply to each successive addition so that when the addition is completed, the entire play area complies...
-
11B-240.1.1 Additions
Where play areas are designed and constructed in phases, the requirements of Section 11B-240 shall apply to each successive addition so that when the addition is completed, the entire play...
-
11B-240.1.1 Additions
Where play areas are designed and constructed in phases, the requirements of Section 11B-240 shall apply to each successive addition so that when the addition is completed, the entire play...
-
1008.4.3 Play Tables
1008.4.3 Play Tables....
-
Height: ADA Standard Section 1008.3.2.2
Each transfer step shall be 8 inches (205 mm) high maximum.
-
Handrail Height: ADA Standard Section 1008.2.5.3.2
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface.