AUTOMATIC DOOR
-
Duration: ADA Standard Section 407.3.3.3
Section 407.3.3.3 covers the current ADA Standards for the duration of an elevators reopening device.
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
-
AUTOMATIC DOOR
AUTOMATIC DOOR. A door equipped with a power operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
Door Hardware [4.13.9]
Door Hardware [4.13.9] Hardware used to operate doors, including handles, pulls, latches and locks, must have a shape that is "easy to grasp with one hand" and does not require tight...
-
4.13.12* Automatic Doors and Power-Assisted Doors
If an automatic door is used, then it shall comply with ANSI/BHMA A156.10‒1985. Slowly opening, low-powered, automatic doors shall comply with ANSI A156.19‒1984....
-
Automatic Door
A door equipped with a power-operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
Contact: ADA Standard Section 407.3.3.2
Section 407.3.3.2 covers the current ADA Standards for the contact requirements of an elevators reopening device.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses....
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses....
-
11B-206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
11B-206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
Reopening Device: ADA Standard Section 407.3.3
Section 407.3.3 covers the current ADA Standards for elevator reopening devices.
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
AUTOMATIC DOOR
A door equipped with a power operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
AUTOMATIC DOOR
A door equipped with a power operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
7.4.7 Openings
Openings in trail tread surfaces, trail resting spaces, and trail passing spaces shall be small enough to prevent passage of a 1/2 inch- (13 mm-) diameter sphere....
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
1132A.3 Width and height of interior doors and secondary exterior doors
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
404.3.4 Doors in Series and Gates in Series
404.3.4 Doors in Series and Gates in Series. Doors in series and gates in series shall comply with 404.2.6....
-
Openings [1017.6]
Openings are gaps in the surface of a trail....
-
Doors
Doors: a. Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6....