Doors and Gates in Series [§404.2.6] At hinged or pivoted doors or gates in series, a separation is required that is at least 48” plus the width of doors or gates swinging into the space...
Search Results "Door Opening Force"
-
Doors and Gates in Series [§404.2.6]
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
-
Error/Omission: The shape of the door hardware requires tight grasping, pinching, and twisting of the wrist to use.
Doors Error/Omission: The shape of the door hardware requires tight grasping, pinching, and twisting of the wrist to use....
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
-
1016.6 Openings
This section requires openings in the surface of outdoor recreation access routes, passing spaces, and resting intervals such as spaces between the boards in a boardwalk and drainage grates...
-
Doors and Gates Operated Only By Security Personnel [§404.1, Ex]
Doors and Gates Operated Only By Security Personnel [§404.1, Ex] Manual doors, doorways, and gates that are designed to be operated only by security personnel, such as guards in...
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
Maneuvering Clearances at Doors [4.13.6]
Maneuvering Clearances at Doors [4.13.6] Pull-side clearance beyond the door swing provides space for a forward reach to door hardware....
- American Specialties Surface Mounted Bottle Opener 0711-B
-
A4.13.10 Door Closers
They are particularly useful on frequently used interior doors such as entrances to toilet rooms....
-
A4.13.10 DOOR CLOSERS
They are particularly useful on frequently used interior doors such as entrances to toilet rooms....
-
5.3.5 Doors
Where provided, doors shall comply with ABAAS section 404. The door shall not swing into or otherwise obstruct the clear floor or ground space required by 5.3.2.1....
-
4.13.9* DOOR HARDWARE
When sliding doors are fully open, operating hardware shall be exposed and usable from both sides....
-
4.13.9* Door Hardware
Handles, pulls, latches, locks, and other operating devices on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, tight pinching...
-
Entrances: ADA Standard Section 206.5.1
Section 206.5.1 covers scoping requirements in the most current ADA Standards for doors, doorways, and gates at entrances.
-
Rooms and Spaces: ADA Standard Section 206.5.2
Section 206.5.2 covers scoping requirements in the most current ADA Standards for accessible routes to rooms and spaces.
-
American Specialties Surface Mounted Bottle Opener Model 0711-B
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Transient Lodging Facilities: ADA Standard Section 206.5.3
Section 206.5.3 covers scoping requirements in the most current ADA Standards for accessible routes to transient lodging facilities.
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....