If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
Search Results "Door Opening Force"
Commonly Searched Documents
- 
    
  
  4.13.10* DOOR CLOSERS
  
- 
    
  
  11B-404.2.7 Door and gate hardware
  Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.... 
- 
    
  
  11B-407.3.1 Type
  Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited.... 
- 
    
  
  POWER-ASSISTED DOOR
  A door used for human passage with a mechanism that helps to open the door, or relieve the opening resistance of a door, upon the activation of a switch or a continued force applied to the... 
- 
    
  
  Automatic Door Break Out Openings
  Automatic Door Break Out Openings. The 1991 Standards do not contain any technical requirement for automatic door break out openings.... 
- 
    
  
  Openings in Beach Access Routes
  Openings are gaps in the surface of a beach access route. Gaps include spaces between the planks on a boardwalk and drainage holes in temporary or permanent surfaces.... 
- 
    
  
  Automatic Doors
  Provisions in section 404.3 address clear width; maneuvering clearance; thresholds; doors and gates in series; operable parts; break out opening; and revolving doors, gates, and turnstiles... 
- 
    
  
  11B-404.2.10 Door and gate surfaces
  Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door... 
- 
    
  
  Minimum Clear Opening
  The issue of minimum clear opening for doors was one of the most widely commented-upon design features of the guidelines.... 
- 
    
  
  Compartment Doors
  Specifications are provided for doors, including their location.... 
- 
    
  
  11B-407.3.6 Width
  The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted.... 
- 
    
  
  § 36.303(g)(6)(ii)
  (ii) A public accommodation may use open movie captioning as an alternative to complying with the requirements specified in paragraph (g)(3) of this section, either by providing open movie... 
- 
    
  
  604.8.1.2 Doors
  Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the... 
- 
    
  
  604.8.1.2 Doors
  604.8.1.2 Doors.... 
- 
    
  
  3.3.16 Door Use
  WhMD users had more difficulty “Opening” door 3, as compared to doors 1 and 2.... 
- 
    
  
  604.8.1.2 Doors
  Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the... 
- 
    
  
  11B-404.3 Automatic and power-assisted doors and gates
  Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10 .... 
- 
    
  
  11B-404.3 Automatic and power-assisted doors and gates
  Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10.... 
- 
    
  
  404.2.4.2 Doorways without Doors or Gates
  404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors.... 
- 
    
  
  404.2.8.1 Door Closers and Gate Closers
  404.2.8.1 Door Closers and Gate Closers.... 
- 
    
  
  404.2.4.2 Doorways without Doors or Gates
  Sliding Doors, and Folding Doors.... 
- 
    
  
  4.6.7 Openings
  Openings in the clear floor or ground space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter.... 
- 
    
  
  404.2.8.1 Door Closers and Gate Closers
  Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum... 
- 
    
  
  11B-206.5.3 Transient lodging facilities