Section 407.4.6.2.2 covers the current ADA Standards for the arrangement of the elevator car control buttons.
Search Results "Call button"
Commonly Searched Documents
-
Arrangement: ADA Standard Section 407.4.6.2.2
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right....
-
11B-411.2.1.2.1 Keypads
Characters and symbols shall be centered on the corresponding button. The number five key shall have a single raised dot....
-
ASME
The communication system must be push button activated. The activation button must be permanently identified with the word "HELP."...
-
Apps
Features can include: Sending emergency voice, text or email messages to a specific group of people Pressing one button that will call, email or text everyone on your contact...
-
12. Q: Do I have to take a sign language interpreter to a call about a violent crime in progress or a similar urgent situation involving a person who is deaf?
If the person being arrested is deaf, the officer can make an arrest and call for an interpreter to be available later at the booking station....
-
A4.31.3 Mounting Height
In localities where the dial-tone first system is in operation, calls can be placed at a coin telephone through the operator without inserting coins....
-
A4.31.3 MOUNTING HEIGHT
In localities where the dial-tone first system is in operation, calls can be placed at a coin telephone through the operator without inserting coins....
- Excel Dryer, Inc. CAST Cover Series HANDS ON® Push Button Activated Hand Dryers and Hair Dryers
-
§ 38.127(c)
., heating and air conditioning controls, lighting controls, call buttons, electrical outlets, etc.) shall be mounted no more than 48 inches, and no less than 15 inches, above the floor...
-
Destination-Oriented Elevators
Destination-oriented elevators are different from typical elevators in that they provide a means of indicating the desired floor at the location of the call button, usually through a key...
-
Symbols: ADA Standard Section 407.4.7.1.3
Section 407.4.7.1.3 covers the current ADA Standards for the designation and indicator symbols on elevator car control buttons.
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
Emergency Communication
The ASME A17.1 code (section 2.27) requires provision of a push button labeled "HELP" which, when activated, initiates a call for help and establishes two-way communication....
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed for the distance from the hall call...
-
Notification: ADA Standard Section 809.5.5.1
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-407.4.6.2.3 Illumination
Car control buttons shall be illuminated....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. ...
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. Reserved. 2....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: Reserved. Reserved....
-
1009.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 in the area of refuge shall activate both a light in the area of refuge indicating that rescue...