The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
Search Results "Call button"
-
11B-407.4.7.1.3 Symbols
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
ASME
The communication system must be push button activated. The activation button must be permanently identified with the word "HELP."...
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed for the distance from the hall call...
-
Emergency Communication
The ASME A17.1 code (section 2.27) requires provision of a push button labeled "HELP" which, when activated, initiates a call for help and establishes two-way communication....
-
Notification: ADA Standard Section 809.5.5.1
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-407.4.6.2.3 Illumination
Car control buttons shall be illuminated....
-
11B-407.4.6.2.3 Illumination
Car control buttons shall be illuminated....
-
4. Pressure Gauge
The device used to make this measurement is called a pressure gauge. A pressure gauge can be manual or electronic....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. ...
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. Reserved. 2....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: Reserved. Reserved....
-
1009.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 in the area of refuge shall activate both a light in the area of refuge indicating that rescue...
-
1009.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 in the area of refuge shall activate both a light in the area of refuge indicating that rescue...
-
11B-407.4.6.2.4 Operation
Car control buttons shall be activated by a mechanical motion that is detectable....
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1....
-
11B-407.4.6.2.4 Operation
Car control buttons shall be activated by a mechanical motion that is detectable....
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1....
-
Location: ADA Standard Section 407.4.6.1
Section 407.4.6.1 covers the current ADA Standards for the location of elevator car controls.
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...