Stairway Handrails Recommendation: In facilities that primarily serve children, a second set of stairway handrails 28” high maximum above stair nosings is advisable....
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
Handrails [§504.6, §505]
-
1.1.3 Walk running slope
Measure for overall running slope (the primary direction of travel) by determining elevations at the ends of the walk, noticeable changes in slope, or at a maximum of 20 ft (6 m) intervals...
-
1134A.8, Item 1
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor....
-
11B-812.7.2 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center....
-
11B-405.3 Cross slope
Curved ramps are not prohibited by Chapter 11B; however, requirements for maximum slope and cross-slope cannot be exceeded.◼...
-
11B-1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
§ 38.23(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches, and the transition from roadway or sidewalk...
-
11B-1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
11B-405.3 Cross slope
Curved ramps are not prohibited by Chapter 11B; however, requirements for maximum slope and cross-slope cannot be exceeded. ◼...
-
2.3.3 Comparison of Dimensions with Standards and other Anthropometric Studies
• Maximum Forces for Hand-operated Controls: Compared to the maximum hand grip strength in a power grip, and lateral and thumb-forefinger pinch grips....
-
Shower Spray Unit
Comments also noted that delivered water should be "temperature limited" to the specified maximum (120 degrees) for consistency with American Society of Safety Engineers (ASSE) standards...
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
Height and Clearances [4.19.2]
Only a portion of the usable clear floor space can "count" as toe space, which is why a maximum depth and minimum height are specified for the front of the underlap of the required clear...
-
2.3.4 Analysis of Door Use Difficulty
The mean, median and range of WhMD user age, occupied width, occupied length and maximum power grip were also reported as we thought that these variables might help explain the door use...
- Cornell University Employment And Disability Institute
-
5. Exception from the Requirements of M302 for Weight Scales with Integral Seats
The MDE NPRM proposed that diagnostic equipment which could be used by patients in multiple positions must comply with the technical criteria for all positions in which it could be used...
- LaCantina Aluminum Thermally Controlled Slider System
- LaCantina Multi-slide Thermally Controlled Aluminum Sliding Door System
-
Co-sharing of Accessible Parking access Aisles by adjacent elevator door allowed?
Given: multistory parking structure circa 1980 with limited head height for vans Issue: Can an elevator door open to and co-share/use an access aisle for an accessible parking space?...
-
11B-405.5 Clear width
Handrails may project into the required clear width of the ramp at each side 3½ inches (89 mm) maximum at the handrail height....
-
11B-405.5 Clear width
Handrails may project into the required clear width of the ramp at each side 3½ inches (89 mm) maximum at the handrail height....