The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
Search Results "Ground Floor"
-
M302.4.1 Clearance in Base
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
11B-217.4.1 Bank requirement
[2010 ADAS] EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....
-
11B-804.3 Kitchen work surface
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, at least one 30 inches (762 mm...
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a 1/2 inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
407.2.2.1 Visible and Audible Signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. EXCEPTIONS: 1....
-
Accessible Miniature Golf Courses
ADAAG addresses only the built environment (structures and grounds). The guidelines do not address operational issues....
-
N. Equal Access for Handicapped Students
Access to vocational programs or courses may not be denied handicapped students on the ground that employment opportunities in any occupation or profession may be more limited for handicapped...
-
2. Federal financial assistance
A number of comments argued for its deletion on the ground that section 504, unlike title VI and title IX, contains no statutory exemption for such contracts....
-
Bathtubs (ADAAG 4.20)
an alternative means of safely transferring an individual into a tub, were generally discouraged, particularly among people with dementia because the experience of being lifted off the ground...
-
III-3.9000 Illegal use of drugs
ILLUSTRATION 2: A medical facility that specializes in care of burn patients may not refuse to treat an individual's burns on the grounds that the individual is illegally using drugs....
-
II-3.8000 Illegal use of drugs
ILLUSTRATION 2: A municipal medical facility that specializes in care of burn patients may not refuse to treat an individual's burns on the grounds that the individual is illegally using...
-
II-3.9000 Discrimination on the basis of association
ILLUSTRATION 2: A local government could not refuse to allow a theater company to use a school auditorium on the grounds that the company has recently performed at an HIV hospice....
-
Feature 2 - Routes to the Building Entrance
All routes must be free of overhanging objects that are less than 80 inches above the ground....
-
Selection of Locations
Previous locations for surface testing did not include the factors associated with a wetlands installation and this particular site such as: A previously undisturbed ground surface...