The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
Search Results "Side Transfer Surface"
-
604.5.2 Rear Wall
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
11B-605.4 Flush controls
Urinals provided in urinal compartments and with hand operated flush controls shall have the controls located on the open side of the urinal....
-
Station Names: ADA Standard Section 810.6.3
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
11B-605.4 Flush controls
Urinals provided in urinal compartments and with hand operated flush controls shall have the controls located on the open side of the urinal....
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
-
Dispersion of Wheelchair Seating Areas (Preamble, Section-by-Section Analysis)
., seats into which persons with mobility impairments can transfer) will also be required....
-
Dispersion of Wheelchair Seating Areas (Section-By-Section Analysis and Response to Comments)
., seats into which persons with mobility impairments can transfer) will also be required....
-
1002.5.4 Wheelchair Storage Space
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required amusement ride seat designed for transfer and shall not overlap any required...
-
H. Door Maneuvering Clearance
On the pull side of each door (i.e.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor...
-
5.3.4 Grab Bars
In such cases, the riser shall have vertical or nearly vertical sides and a flat area on each side of the seat that is about 3 inches (75 millimeters) wide....
-
Scoping [4.1.3(20)]
Specifications in 4.34.2 and 4.34.3 were modified in June 1993 to allow either a forward or side approach and to provide further guidance on side reach heights....
-
5.3.4 Grab Bars
In such cases, the riser shall have vertical or nearly vertical sides and a flat area on each side of the seat that is about 3 inches (75 millimeters) wide. ...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Exercise Equipment and Machines
If the clear space is enclosed on three sides (e.g., by walls or the equipment itself), the clear space must be at least 36 by 48 inches....
- Landscape Forms Inc. FGP Trash Receptacle
- Zurn Industries Stop and Supply Protector
- Zurn Industries Offset Drain Protector
- Zurn Industries Combination Kit: One Trap Protector and One Supply Stop Protector
-
Curb or Barrier: ADA Standard Section 405.9.2
Section 405.9.2 covers the current ADA Standards for a curb or barrier that is provided as edge protection at a ramp.
-
11B-809.12 Electrical receptacles, controls and switches
When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 1/2 inches (650 mm) maximum in depth....
-
11B-809.12 Electrical receptacles, controls and switches
When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 1/2 inches (650 mm) maximum in depth....
-
Elongated surface openings must be perpendicular to the dominant direction of travel, but what if there is no dominant direction of travel?
When there is no dominant direction of cross traffic, openings must be limited to ½” in both dimensions. Where space allows accessible routes to completely bypass the area with...