When the breast platform lowers to its required minimum height of 26 inches, the resulting toe height is 10 inches above the ground....
Search Results "Minimum Dimension"
Commonly Searched Documents
-
5.8.2.5 Toe Height Recommendation
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
-
Clear floor space at Lav
Terry, You should identify the minimum dimensions of the clear floor space at the Lav....
-
Bike Lane Width
The AASHTO Guide for the Development of Bicycle Facilities (p. 22) recommends a minimum width for bike lanes of 1.2 m (4 ft).(2) While this dimension appears to be adequate to accommodate...
-
4.21.2 Size and Clearances
Minimum guidelines for roll-in shower stalls are based on residential size fixtures (30" x 60" minimum or the space used by a standard residential tub/shower unit) and spaces (30" minimum...
-
Must the minimum number of spaces be determined separately for each parking facility on a site or can it be based on the collective total of spaces provided on a site?
The minimum number of accessible parking spaces, including van accessible spaces, must be calculated separately for each parking facility on a site....
-
1016.6 Openings
Where possible, drainage grates should be located outside the minimum clear width of the recreation access route....
-
11B-703.6.1 Pictogram field
Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field....
-
Outdoor Constructed Features
The proposed rule based the size of the clear ground space at outdoor constructed features on the dimensions for clear floor or ground surfaces in 305.2 of the Architectural Barriers Act...
-
1016.6 Openings
Where possible, drainage grates should be located outside the minimum clear width of the outdoor recreation access route....
-
5.2.2.1 Transfer Surface Width Recommendations for M302
5.2.2.1 Transfer Surface Width Recommendations for M302 The Committee recommends 21 inches for the minimum width of the transfer surface of examination chairs and other equipment primarily...
-
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs
The border dimension of the pictogram shall be 6 in (152 mm) minimum in height....
-
1016.6 Openings
Where possible, drainage grates should be located outside the minimum clear width of the outdoor recreation access route....
-
11B-703.6.1 Pictogram field
Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field....
-
Parallel Curb Ramps (R304.3) (Section-by-Section Analysis)
The turning space must be 1.2 meters (4 feet) minimum by 1.2 meters (4 feet) minimum, and is permitted to overlap other turning spaces and clear spaces....
-
604.2 Location
The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
11B-703.6.1 Pictogram field
Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field. ...
-
5.4.2.1 Transfer Support Length Recommendation for Stretchers
5.4.2.1 Transfer Support Length Recommendation for Stretchers On Stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are positioned...
-
Doorways [4.8.4]
Keeping the door swing clear of minimum landing dimensions is a good idea, especially at the bottom of ramps since people using wheelchairs may exit them with some force and speed....
-
5.2.1.2 Transfer Surface Depth Recommendation for M301
The Committee easily supported this increase as existing equipment already encompassed this dimension. The Committee reviewed anthropometric data from a variety of sources. Dr....
-
Alterations [4.1.6(1)(f) & (k)]
For example, if the planned scope of work is limited to replacement of an elevator cab's control panel, then at a minimum the new control panel must comply to the maximum extent feasible...
-
Openings: ADA Standard Section 302.3
Section 302.3 covers the current ADA Standards for floor and ground surface openings.
-
407.12.3.1 Unobstructed Forward Reach (Section-by-Section Analysis)
Section-by-Section Analysis) This section proposes that, where an unobstructed forward reach is provided, the operable part must be located 48 inches high maximum and 15 inches high minimum...
-
4.10.3 Hall Call Buttons
Call buttons shall be a minimum of 3/4 in (19 mm) in the smallest dimension. The button designating the up direction shall be on top. (See Fig. 20.) Buttons shall be raised or flush....