A turning space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided at the bottom of the curb ramp and shall be permitted to overlap other turning spaces and clear spaces....
Search Results "Minimum Dimension"
Commonly Searched Documents
-
R304.3.1 Turning Space
-
4.1.6(4)(c)
(ii) Where existing shaft or structural elements prohibit strict compliance with 4.10.9, then the minimum floor area dimensions may be reduced by the minimum amount necessary, but in no...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Accessible Pathway & Corridor: Minimum Clear Floor Space Required for 360-degree Turn
The minimum space required to perform a complete 360-degree turn within moving or knocking down any of the walls was recorded....
-
M305.3 Standing Supports (Section-by-Section Analysis)
and whether standing supports can provide a 1½ inch minimum clearance around the gripping surface....
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
T505.3 Location of Operable Parts
Operable parts shall be located so that they are reachable by passengers using wheelchair when parked in a clear space 30 inches (760 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
Introduction
Introduction The proposed guidelines for medical diagnostic equipment recommends a minimum transfer surface 30 in. (760mm) wide and 15 in. (381mm) deep. At the request of the U.S....
-
Knee & Toe Space [M303.2.4]
25-inch absolute dimension....
-
1011.2.1 Size and Location
The size of the clear ground space is based on the dimensions for maneuvering clearance at clear floor or ground spaces that are confined on all or part of three sides in 305.7 of the Architectural...
-
14.3 Q...are there any requirements for the inside dimensions of these individual parking garages?
A. Yes. These garages would be public and common use space, even though the individual garages may be assigned to a particular dwelling unit. Therefore, at least two percent of the...
-
Standing Supports (M304.3 and M305.3)
The minimum and maximum height of the bottom of the support above the standing surface is based on anthropometric data for the 1th percentile woman (minimum) and the 99th percentile man...
-
Graphic Conventions [3.1]
Dimensions in ADAAG and this manual are absolute unless noted as a maximum or minimum. ADAAG includes in text and figures the metric equivalent (in millimeters)....
-
407.12.3.2.2 Knee and Toe Space (Section-by-Section Analysis)
407.12.3.2.2 Knee and Toe Space (Section-by-Section Analysis) This section proposes dimensions for knee and toe space under ICT when an obstructed forward reach is provided....
-
Clear Floor Space [4.16.2]
Clear Floor Space [4.16.2] ADAAG (Figure 28) specifies the amount of space required at an accessible toilet, not the minimum room size, which must also include turning space, clear floor...
- Figure 408.4.1(c) Limited-Use/Limited-Application (LULA) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 408.4.1(b) Limited-Use/Limited-Application (LULA) Elevator Car Dimensions – Drawing from the U.S. Access Board
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
The transfer surface should be 28 inches wide minimum and 21 inches deep minimum....
-
5.2.2.2 Transfer Surface Depth Recommendation for M302
5.2.2.2 Transfer Surface Depth Recommendation for M302 The Committee recommends a minimum depth requirement of 17 inches for equipment used by patients in seated positions....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Construction Specification Institute
For longitudinal lines, measurements were to be taken in minimum 5 - foot lengths running parallel to the long dimension, with one measurement line per 3 feet of width and within 2 feet...
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...