407.12.1.2 Vertical Plane for Forward Reach (Section-by-Section Analysis) This section proposes that, where a forward reach is provided, the vertical reference plane must be, at a minimum...
Search Results "Minimum Dimension"
-
407.12.1.2 Vertical Plane for Forward Reach (Section-by-Section Analysis)
-
3.1 GRAPHIC CONVENTIONS
Dimensions that are not marked "minimum" or "maximum" are absolute, unless otherwise indicated in the text or captions....
-
409.2 Call Buttons
Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension and shall comply with 309....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
4.1.6(3)(c)(ii)
(ii) Where existing shaft configuration or technical infeasibility prohibits strict compliance with 4.10.9, the minimum car plan dimensions may be reduced by the minimum amount necessary...
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
4.3.3 Clear Floor Area
4.3.3 Clear Floor Area Clear floor area dimensions are the basis for the minimum required size of spaces used by wheeled mobility users (e.g. platform/wheelchair lifts) and for spaces...
-
407.2.1.2 Size
Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension. EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
M305.2.4 Cross Section (Section-by-Section Analysis)
Specifically, the Access Board indicated it was considering requiring circular cross sections to have an outside diameter of 1¼ inches minimum and 2 inches maximum, and transfer supports...
-
3.1 Graphic Conventions
Dimensions that are not marked minimum or maximum are absolute, unless otherwise indicated in the text or captions. Table 1 Graphic Conventions...
-
Clearance in Base (M301.4.1 and M302.4.1)
M301.4.1 and M302.4.1 would require the clearance in the base to be 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge...
-
407.2.1.2 Size
Call buttons shall be 3/4 inch (19 mm) minimum in the smallest dimension. EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
407.2.1.2 Size
Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension. EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
RECOMMENDATION OF 19-INCH LOWER ADJUSTABLE HEIGHT AS THE MINIMUM ACCESSIBILITY STANDARD SEPTEMBER 27, 2013
RECOMMENDATION OF 19-INCH LOWER ADJUSTABLE HEIGHT AS THE MINIMUM ACCESSIBILITY STANDARD SEPTEMBER 27, 2013 SUBMITTED BY: The Brewer Company (Jack DeBraal, committee member) Hausmann...
-
11B-609.3 Spacing
The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-609.3 Spacing
The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
- Eco Grip Flooring 2min HD
-
5.8.2 Knee and Toe Clearance Under Breast Platform
The overall knee and toe space should be increased to a minimum of 28 inches deep, from the initially proposed 25 inch absolute dimension; increasing the knee clearance directly underneath...
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Advisory 11B-302.3 Openings....
-
11B-302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Advisory 11B-302.3 Openings....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 90-degree Turn
The minimum space required to perform a complete 90-degree turn within moving or knocking down any of the walls was recorded....
- Figure 408.4.1(a) Limited-Use/Limited-Application (LULA) Elevator Car Dimensions – Drawing from the U.S. Access Board