The running slope of any segment of an outdoor recreation access route shall not be steeper than 1:10 (10%). ...
Search Results "Bench (Outdoor)"
-
1016.7.1 Maximum Running Slope and Segment Length
-
1016.7.1 Maximum Running Slope and Segment Length
The running slope of any segment of an outdoor recreation access route shall not be steeper than 1:10 (10%)....
-
1011.2.4 Openings
Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings. Where possible, drainage...
-
1016.8 Resting Intervals
Resting intervals shall comply with 1016.8.
-
1016.8.1 Length
The resting interval length shall be 60 inches (1525 mm) long minimum.
-
Technical Requirements [1016]
[See subsections ...]
-
Cross Slope [1016.7.2]
Cross slope is the side-to-side slope of the surface of an ORAR. When the surface is constructed of concrete, asphalt, or boards, the cross slope must be no steeper than 1:48 (2...
-
2.7 Tread Obstacles
Where tread obstacles exist on the surface of an ORAR, they shall not exceed 1 inch (25 mm) in height. Where the surface is paved or is elevated above the natural ground,...
-
5.3.1 General
Pit toilets may only be provided in FS recreation sites with a Recreation Site Development Scale level of 2 or less or at remote cabin locations. All pit toilets shall comply with...
-
3.2.2 ORARs in Camping Units
Connections shall be provided between site furnishings and constructed features in camping units as well as between accessible camping units, parking areas, and accessible common use...
-
1016.8.1 Length
This section requires resting intervals to be 60 inches long minimum.
-
1011.2.4 Openings
This section requires openings in the clear ground space such as drainage grates to not allow passage of a sphere more than 1/2 inch in diameter. Where possible, drainage grates...
-
2.5.2 Length
The resting interval length shall be 60 inches (1525 mm) long minimum.
-
2.5 Resting Intervals
Resting intervals shall comply with 2.5.
-
2.6.1 Size
The passing space shall be either:
-
4.5.1 General
Where trash, recycling, and other essential containers are provided, each shall comply with section 4.5. Exception 1. Fifty percent of the bins in multi-bin containers are...
-
1016.8 Resting Intervals
Resting intervals shall comply with 1016.8.
-
1016.8.1 Length
The resting interval length shall be 60 inches (1525 mm) long minimum.
-
1011.2.4 Openings
Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings. Where possible, drainage...
-
1016.5 Obstacles
This section contains technical requirements for obstacles on outdoor recreation access routes, passing spaces, and resting intervals....
-
Utilities at Recreation Sites
In general, connect electricity hookups, drinking water faucets, outdoor rinsing showers, utility sinks, sewer hookups, and other utilities that are provided in recreation sites to the other...
-
Viewing Areas
Viewing areas in recreation settings must be located along an outdoor recreation access route that connects to the other major features at the site, including the parking area....
-
1016.4.1 Size
Vertical alignment at the intersection of the outdoor recreation access routes that form the T-shaped space shall be nominally planar. Advisory 1016.4.1 Size....
-
1016.9 Protruding Objects
This section requires constructed elements on outdoor recreation access routes, resting intervals, and passing spaces to comply with the technical requirements for protruding objects in...