Clear floor or ground space around a water hydrant shall be 48 inches (1220 mm) by 72 inches (1830 mm) with the long side of the space adjoining an outdoor recreation access route, trail...
Search Results "Bench (Outdoor)"
-
4.7.6 Water Hydrant Clear Floor or Ground Space
-
F245.4.3 Routes to Adjacent Recreation Facilities
Where a circulation path connects picnic facilities and adjacent recreation facilities, at least one outdoor recreation access route shall connect picnic units with mobility features to...
-
Built-in Elements
BUILT-IN ELEMENTS Dining/work surfaces 11B-226, 11B-902.2 Benches 11B-903.2...
-
Built-in Elements
BUILT-IN ELEMENTS Dining/work surfaces 11B-226, 11B-902.2 Benches 11B-903.2...
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Fire rings, grills, fireplaces, and wood stoves shall comply with 1011.5. Advisory 1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves. Fire rings with double walls or...
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction. EXCEPTION: Where the surface is other than asphalt, concrete, or boards, slopes not...
-
1016.7.2 Cross Slope
The cross slope shall not be steeper than 1:48. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when...
-
Passing Spaces [1016.4]
Where the clear width of an ORAR is less than 60 inches, passing spaces must be provided at intervals of at least 200 feet. Passing spaces must be: A minimum space of 60...
-
Using the ORAR Exceptions [F202.3, Exception 4 and 1016, Exceptions 1, 2, and 3]
Where elements or spaces in camping and picnic facilities, viewing areas, or trailheads are altered but the circulation path to the altered element or space is not changed, the...
-
Protruding Objects [1016.9]
Objects that protrude into ORARs, passing spaces, and resting intervals can pose hazards to people who are blind or have low vision. Constructed elements, such as signs on ORARs,...
-
3.2.5.1 Walk-In Camping
Where walk-in camping is provided, an ORAR connecting the camp living area to the parking area shall be provided in accordance with section 2.0.
-
6.11 Protruding Objects
Constructed features, including signs, shall not extend into the space above a beach access route more than 4 inches (100 mm) if they are between 27 inches (685 mm) and 80...
-
2.2 Surface
The surface of an ORAR shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
4.2 Fire Rings, Grills, Fireplaces, and Wood Stoves
[See subsections ...]
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Fire rings, grills, fireplaces, and wood stoves shall comply with 1011.5. Advisory 1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves. Fire rings with double walls or...
-
1011.2.3 Slope
This section requires the slope of the clear ground space to not be steeper than 1:48 in any direction. Where the surface is other than asphalt, concrete, or boards, slopes not...
-
2.5.1 Location
A resting interval shall be provided between each ORAR segment, in compliance with section 2.4.1. Depending on the design and location, the intersection of two ORARs may act as a...
-
4.5.5 Controls and Operating Mechanisms
Controls and operating mechanisms shall comply with the operable parts requirements in sections 308 and 309.4 of the ABAAS. Exception. Trash and recycling containers with hinged...
-
2.4.2 Cross Slope
The cross slope of an ORAR shall be no more than 1:33 (3 percent). Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48...
-
1016.7.2 Cross Slope
The cross slope shall not be steeper than 1:48. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when...
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction. EXCEPTION: Where the surface is other than asphalt, concrete, or boards, slopes not...
-
F245.4.2 Routes to and Within Common Use and Public Use Areas
Common use and public use areas serving picnic units with mobility features shall provide outdoor recreation access routes in accordance with F245.4.2....
- Pilot Rock ASW-20 Series Grill
-
1016.4 Passing Spaces
Outdoor recreation access routes with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 1016.4 at intervals of 200 feet (61 m) maximum. ...