A combined circle and triangle symbol shall be located at entrances to unisex toilet and bathing facilities....
Search Results "Shall"
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
-
11B-502.3.4 Location
Access aisles shall not overlap the vehicular way....
-
1133A.4.1 Repositionable countertops
Repositionable countertops shall be provided in a minimum of 5 percent of the covered multifamily dwelling units....
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
221.2.3 Lines of Sight and Dispersion
Wheelchair spaces shall provide lines of sight complying with 802.2 and shall comply with 221.2.3. In providing lines of sight, wheelchair spaces shall be dispersed....
-
504.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
-
407.3.3 Reopening Device
Elevator doors shall be provided with a reopening device complying with 407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an...
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3....
-
612.2 Bench
Where seating is provided in saunas and steam rooms, at least one bench shall comply with 903. Doors shall not swing into the clear floor space required by 903.2....
-
904.4.2 Forward Approach
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided....
-
Sec. 469.053(a)
(a) The presiding officer of the commission, with the commission’s approval, shall appoint an advisory committee for the architectural barriers program....
-
R409.10.3 Bottom Extension at Stairways
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
502.3 Accessibility Services
Platform software and software tools that are provided by the platform developer shall provide a documented set of accessibility services that support applications running on the platform...
-
11B-604.8 Toilet compartments
Wheelchair accessible toilet compartments shall meet the requirements of Sections 11B-604.8.1 and 11B-604.8.3 _|Coat Hooks and Shelves|_....
-
R409.10.2 Top Extension at Stairways
At the top of a stair flight, handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beginning directly above the first riser nosing....
-
4.8.5* Handrails
If a ramp run has a rise greater than 6 in (150 mm) or a horizontal projection greater than 72 in (1830 mm), then it shall have handrails on both sides....
-
4.19.3 Clear Floor Space
A clear floor space 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a lavatory to allow forward approach....
-
4.19.3 CLEAR FLOOR SPACE
A clear floor space 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a lavatory to allow forward approach....
-
11B-503.3.3 Marking
Access aisles shall be marked with a painted borderline around their perimeter....
-
§ 37.9(d)(3)(i)
(i) The entity shall contact individuals with disabilities and groups representing them in the community....
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3....
-
904.4.2 Forward Approach
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided....
-
612.2 Bench
Where seating is provided in saunas and steam rooms, at least one bench shall comply with 903. Doors shall not swing into the clear floor space required by 903.2....
-
810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1) and shall have a clear...