Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3. ...
Search Results "Vertical Clearance"
Commonly Searched Documents
-
306.3.1 General
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
- Rockwood Manufacturing Company BFRC24 Vertical Rod Cover
-
11B-804.2 Clearance
Where a pass through kitchen is provided, clearances shall comply with Section 11B-804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with Section 11B-804.2.2....
-
11B-804.2 Clearance
Where a pass through kitchen is provided, clearances shall comply with Section 11B-804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with Section 11B-804.2.2....
-
11B-804.2 Clearance
Where a pass through kitchen is provided, clearances shall comply with Section 11B-804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with Section 11B-804.2.2....
-
5.8.2.3 Overall Knee and Toe Clearance
5.8.2.3 Overall Knee and Toe Clearance. The overall knee and toe space should be increased to a minimum of 28 inches....
-
1010.1.4 Floor elevation
Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal (2-percent slope)....
-
Clear Floor Space [4.2.4]
Clearances below plumbed fixtures are further defined specifically for toe space because of piping below the fixture....
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors.
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
5.8.2.6 Clearance Depth at Toe Height Above the Ground
5.8.2.6 Clearance Depth at Toe Height Above the Ground. The toe clearance depth should be 22 inches minimum at toe height....
-
Forward Approach
Clearances for a forward approach are required at cantilevered units....
- Figure 304.3.2 T-Shaped Turning Space – Drawing from the U.S. Access Board
-
410.4 Platform to Runway Clearance
The clearance between the platform sill and the edge of any runway landing shall be 1 inch (32 mm) maximum....
-
409.4.3 Platform to Hoistway Clearance
The clearance between the car platform and the edge of any landing sill shall be 1-½ inch (38 mm) maximum....
-
410.4 Platform to Runway Clearance
The clearance between the platform sill and the edge of any runway landing shall be 1 inch (32 mm) maximum....
-
5.8.2.2 Knee Clearance Depth at 27” Above the Ground
5.8.2.2 Knee Clearance Depth at 27” Above the Ground. The knee clearance should be increased at 27 inches above the ground to 18 inches minimum....
-
5.8.2.2 Knee Clearance Depth at 27” Above the Ground
5.8.2.2 Knee Clearance Depth at 27” Above the Ground The Committee recommends increasing the knee clearance at 27 inches above the ground to 18 inches minimum....
-
409.4.3 Platform to Hoistway Clearance
The clearance between the car platform and the edge of any landing sill shall be 1 1/2 inch (38 mm) maximum....
-
Doors
Doors The exception from latch-side maneuvering clearances is allowed only at acute care bedrooms, not throughout a hospital....