Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
Search Results "Vertical Clearance"
Commonly Searched Documents
-
306.1 General
-
Is an accessible route required to rooftop levels?
In facilities where an accessible route is required to each story (§206.2.3), an accessible route must serve rooftop levels that contain public or common use spaces or elements that...
-
Do basements count in determining a facility’s story count?
As defined in the Standards, a “story” pertains to those portions of buildings “designed for human occupancy included between the upper surface of a floor and upper surface of the...
-
407.4.3 Platform to Hoistway Clearance
407.4.3 Platform to Hoistway Clearance. The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum....
-
4.1.2(5)(b)
The vertical clearance at such spaces shall comply with 4.6.5. All such spaces may be grouped on one level of a parking structure....
-
804.2 Clearance
804.2 Clearance. Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with 804.2.2....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
804.2 Clearance
Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with 804.2.2....
-
804.2 Clearance
Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with 804.2.2....
-
407.12.3.1 Unobstructed Forward Reach (Section-by-Section Analysis)
An unobstructed forward reach, for purposes of this section, occurs when the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference...
-
1017.8.4 Turning Space
The vertical alignment of the trail tread, turning space, and resting interval is required to be nominally planar (i.e., as flat as possible) so that all the wheels of a mobility device...
-
Bedside Clearances
Bedside Clearances Clearance at least 36 inches wide is required on each side of beds. Where more than one bed is provided, this space can overlap....
-
Philips Healthcare
recommendations included in the Advisory Committee Report dated September 13th, 2013 represent the consensus of the committee With the following exceptions: 1) NPRM M303.2.4 Knee and Toe Clearance...
-
When alterations are made on an upper story of a facility, is vertical access required?
If an alteration includes installation of a stair or escalator where none existed previously and involves major structural modifications, an accessible route between levels served by...
-
1018.5 Obstacles
The vertical alignment of boards on a beach access route or removable sections of a beach access route can be obstacles....
-
11B-306.2.5 Width
Toe clearance shall be 30 inches (762 mm) wide minimum. FIGURE 11B-306.2 TOE CLEARANCE...
-
11B-306.3.5 Width
Knee clearance shall be 30 inches (762 mm) wide minimum. FIGURE 11B-306.3 ‡‡ KNEE CLEARANCE...
-
1018.5 Obstacles
Obstacles on beach access routes and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
1018.5 Obstacles
Obstacles on beach access routes and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
306.2.5 Width
Toe clearance shall be 30 inches (760 mm) wide minimum. Figure 306.2 Toe Clearance...
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)
An obstructed forward reach, for purposes of this section, occurs when the operable part is located behind the leading edge of the maximum protrusion within the length of the vertical reference...