Search Results "Toilet Room Signage"
Commonly Searched Documents
-
11B-603 Toilet and bathing rooms
-
68.101(c)(5)(E) Signage at toilet rooms or bathrooms
(E) Signage at toilet rooms or bathrooms shall comply with TAS 703....
-
Signage
Error/Omission: Where permanent room identification signage is provided, it is mounted in the wrong location....
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
Signs: ADA Standard Section 703
[See subsections ...]
-
Signs: ADA Standard Section 216
Section 216 covers scoping requirements in the current ADA Standards for signs.
-
11B-216 Signs
[See subsections ...]
-
11B-703 Signs
[See subsections ...]
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60...
-
Unisex Toilet Rooms
Comments advised revising requirements for unisex toilet and bathing rooms for greater consistency with model building codes....
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...
-
11B-216.1 General
The substantive difference between the CBC and 2010 ADA Standards scoping for signage at parking facilities is that signs identifying permanent rooms and spaces, directional and informational...
-
11B-213.2 Toilet rooms and bathing rooms
SECTION TITLE NOTES 11B-213.2 Toilet rooms and bathing rooms. ...
-
Toilet Facilities and Bathing Facilities: ADA Standard Section 809.4
Toilet and bathing fixtures required to comply with 603 through 610 shall be located in the same toilet and bathing area, such that travel between fixtures does not require travel between...
-
11B-213.2.2 Unisex (Patient) toilet rooms in medical care and long-term care facilities
Common-use unisex toilet rooms for exclusive patient use not located within patient bedrooms shall contain a lavatory and one water closet....
-
Toilet and Bathing Facilities: ADA Standard Section 806.2.4
At least one bathroom that is provided as part of a guest room shall comply with 603....
-
Signage [4.30]
Signage [4.30] The Society for Environmental Graphic Design (SEGD) has prepared guidance in applying ADAAG signage requirements based on certain industry conventions....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
C. Toilet Rooms:
For all inaccessible toilet rooms PSE shall provide directional signage indicating the location of the nearest accessible toilet rooms. ...
-
Installation Height and Location: ADA Standard Section 703.4
Signs with tactile characters shall comply with 703.4.
-
Stroke Thickness: ADA Standard Section 703.5.7
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
-
6.4 Patient Toilet Rooms
Where toilet/bath rooms are provided as a part of a patient bedroom, each patient bedroom that is required to be accessible shall have an accessible toilet/bath room that complies with 4.22...