Scoping requirements for signs cover room designations (216.2) and directional and informational signs (216.3)....
Search Results "Toilet Room Signage"
Commonly Searched Documents
-
216 Signs
-
Toilet Compartments: ADA Standard Section 604.9.7
Section 604.9.7 covers the current ADA Standards for children's toilet compartments.
-
Vanity Counter Top Space: ADA Standard Section 806.2.4.1
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
805.4 Toilet and Bathing Rooms
Toilet and bathing rooms that are provided as part of a patient or resident sleeping room shall comply with 603....
-
805.4 Toilet and Bathing Rooms
Toilet and bathing rooms that are provided as part of a patient or resident sleeping room shall comply with 603....
-
4.30.6 Mounting Location and Height
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
B. Braille Signs
Do the wall mounted signs provided for the rooms listed above have Braille and raised letters so that they can be read by persons who are blind or have low vision?...
-
Toilet Compartments: ADA Standard Section 213.3.1
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
-
11B-805.2.4 Toilet and bathing rooms
Toilet and bathing rooms that are provided as part of patient bedrooms and resident sleeping rooms complying with Section 11B-223.2 or 11B-223.3 shall comply with Section 11B-603....
-
11B-805.2.4 Toilet and bathing rooms
Toilet and bathing rooms that are provided as part of patient bedrooms and resident sleeping rooms complying with Section 11B-223.2 or 11B-223.3 shall comply with Section 11B-603....
-
11B-805.2.4 Toilet and bathing rooms
Toilet and bathing rooms that are provided as part of patient bedrooms and resident sleeping rooms complying with Section 11B-223.2 or 11B-223.3 shall comply with Section 11B-603....
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both.
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
Single-User Toilet Rooms: Split Plumbing
Single-User Toilet Rooms: Split Plumbing Water closets and lavatories can be located on opposing walls....
-
Visual Characters: ADA Standard Section 703.5
Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to...
-
11B-703.5 Visual characters
Visual characters shall comply with Section 11B-703.5. Exception: Where visual characters comply with Section 11B-703.2 and are accompanied by Braille complying with Section...
-
Toilet Buildings and Pit Toilets
Vault toilets, flush toilets, or composting toilets are typical at these sites....
-
4.1.2(15)
In addition, permanent signage that identifies rooms and spaces shall also comply with 4.30.4 and 4.30.6....
-
11B-813.1 Location
Adult changing facilities shall be provided within a unisex (single-user or family) toilet room or other similar private room....
-
Line Spacing: ADA Standard Section 703.5.9
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C 1991 Standards Plan-2A: 1991 Standards Minimum with In-Swinging Door 5’-0" x 8’-6" • 42.50...