All bathrooms within the dwelling unit shall be designed to comply with the following: 1. Toilet, bathing and shower facilities shall comply with Section 1134A.4. 2....
Search Results "Multifamily Dwelling (HUD 504)"
-
1134A.2 Number of complying bathrooms
-
1134A.3 Powder rooms
All powder rooms shall be designed to comply with Section 1134A.2, Option 2, Items 8 through 12. When the powder room is the only toilet facility located on an accessible level, it...
-
1134A.3 Powder rooms
All powder rooms shall be designed to comply with Section 1134A.2, Option 2, Items 8 through 12. When the powder room is the only toilet facility located on an accessible level, it...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door,...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door,...
-
1134A.5 Bathtubs
Bathtubs required to be accessible shall comply with this section.
-
1134A.5 Bathtubs
Bathtubs required to be accessible shall comply with this section. 1. Floor space. There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219...
-
1134A.5, Item 1
1. Floor space. There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to...
-
1134A.5, Item 2
2. Reinforced walls for grab bars. A bathtub installed without surrounding walls shall provide reinforced areas for the installation of floor-mounted grab bars. Where a bathtub is...
-
1134A.5, Item 3
3. Bathtub controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force...
-
1134A.5, Item 4
4. Shower unit. A shower spray unit is not required in bathtubs.
-
1134A.5, Item 5
5. Bathtub enclosures. Doors and panels of bathtub enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged doors shall open outward. Glazing...
-
1134A.6 Showers
Showers required to be accessible shall comply with this section.
-
1134A.6 Showers
When one or more shower stalls are provided within the same dwelling units, at least one shower stall shall comply with one of the following requirements. 1.1....
-
1134A.6, Item 1
When one or more shower stalls are provided within the same dwelling units, at least one shower stall shall comply with one of the following requirements....
-
1134A.6, Item 1.1
1.1. The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or
-
1134A.6, Item 1.2
1.2. The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm). A water closet may project...
-
1134A.6, Item 1.3
1.3. Other shower stall configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall...
-
1134A.6, Item 2
2. Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum or...
-
1134A.6, Item 3
3. Floor space. A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the...
-
1134A.6, Item 4
4. Reinforced walls for grab bars. Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor. The grab...
-
1134A.6, Item 5
5. Thresholds. When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal...
-
1134A.6, Item 6
6. Shower controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force...
-
1134A.6, Item 7
7. Shower enclosures. Doors and panels of shower enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged shower doors shall open outward....