It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: The slopes of the undisturbed site...
Search Results "Multifamily Dwelling (HUD 504)"
-
TEST NO. 1 – INDIVIDUAL BUILDING TEST
-
TEST NO. 2 – SITE ANALYSIS TEST
Determine the requirement of providing an accessible route to planned multifamily dwellings based on the topography of the existing natural terrain....
-
TEST NO. 2 – SITE ANALYSIS TEST
Determine the requirement of providing an accessible route to planned multifamily dwellings based on the topography of the existing natural terrain....
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
-
8. A condominium (or apartment) development has to comply only with CBC Chapter 11A.
The California Fair Employment and Housing Act (FEHA) requires all "covered multi-family dwellings" designed and constructed for first occupancy after March 13, 1991 to be readily accessible...
-
11B-233.3.4.3 Alterations to residential dwelling units with adaptable features
The building standards for residential dwelling units with adaptable features do not apply to the alteration, repair, rehabilitation or maintenance of residential dwelling units constructed...
-
11B-233.3.4.3 Alterations to residential dwelling units with adaptable features
The building standards for residential dwelling units with adaptable features do not apply to the alteration, repair, rehabilitation or maintenance of residential dwelling units constructed...
-
11B-233.3.4.3 Alterations to residential dwelling units with adaptable features
The building standards for residential dwelling units with adaptable features do not apply to the alteration, repair, rehabilitation or maintenance of residential dwelling units constructed...
-
9. I do not need to provide access to my rental office because I do not have disabled tenants in my housing facility.
All common use areas serving covered multifamily dwellings are also subject to the accessibility requirements in Chapter 11A, and the accessibility and reasonable accommodations requirements...
-
1128A.1 General
Covered multifamily dwelling units shall be adaptable and accessible into and throughout the dwelling unit as provided in this division....
-
SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS
SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS...
-
1130A.1 General
An accessible route shall be provided through all rooms and spaces of the dwelling unit....
-
1130A.2 Width
The accessible route into and throughout covered multifamily dwelling units shall be at least 36 inches (914 mm) wide....
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
1132A.10 Door signal devices
Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
-
1133A.4.1 Repositionable countertops
Repositionable countertops shall be provided in a minimum of 5 percent of the covered multifamily dwelling units. Repositionable countertops shall comply with the following:...
-
SECTION 1134A BATHING AND TOILET FACILITIES
SECTION 1134A BATHING AND TOILET FACILITIES
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section....
-
1134A.2 Number of complying bathrooms
All bathrooms within the dwelling unit shall be designed to comply with the following: 1. Toilet, bathing and shower facilities shall comply with Section 1134A.4. 2. ...
-
1134A.3 Powder rooms
1134A.3 Powder rooms. All powder rooms shall be designed to comply with Section 1134A.2, Option 2, Items 8 through 12. When the powder room is the only toilet facility located on an...
-
1134A.4 Sufficient maneuvering space
1134A.4 Sufficient maneuvering space. Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other...
-
1134A.5 Bathtubs
1134A.5 Bathtubs. Bathtubs required to be accessible shall comply with this section.
-
1134A.5, Item 1
1. Floor space. There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower...