Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
Search Results "Door Maneuvering Clearance"
-
11B-1009.4.1 Clear deck space
-
§ 38.125(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a seating location...
-
11B-1009.4.1 Clear deck space
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
907.2.6.1 Group I-2
Corridor smoke detection is not required where patient room doors are equipped with automatic door-closing devices with integral smoke detectors on the room sides installed in accordance...
-
A4.33.3 Placement of Wheelchair Locations
Building/life safety codes set minimum distances between rows of fixed seats with consideration of the number of seats in a row, the exit aisle width and arrangement, and the location of exit doors...
-
410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
Furnishings and Equipment
In addition, placement of non-fixed elements can affect the accessibility of an area by encroaching into accessible routes and clearances....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The circle symbol shall contrast with the door, either light on a dark background or dark on a light background....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The circle symbol shall contrast with the door, either light on a dark background or dark on a light background....
-
4.3.11.1(5)
) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour fire-resistive doors...
-
4.30.6 MOUNTING LOCATION AND HEIGHT
Interior signage shall be located alongside the door on the latch side and shall be mounted at a height of between 54 in and 66 in (1370 mm and 1675 mm) above the finished floor....
-
§ 38.31(a)
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread or lift platform....
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
- Lighthouse International
-
4.31.2 CLEAR FLOOR OR GROUND SPACE
Figure 44 Mounting Heights and Clearances for Telephones...
-
A4.34.6.8 REFRIGERATOR/FREEZERS
Locating refrigerators so that their doors can swing back 180 degrees is more convenient for wheelchair users....
-
68.10(12) Element
., telephone, curb ramp, door, drinking fountain, seating, water closet, or public right-of-way....
-
§ 37.13(b)
(b) The vehicle door height requirements for vehicles over 22 feet identified in §38.25(c) of this title apply to solicitations for vehicles under this part after January 25, 1992....
-
§ 38.63(b) Exception
Between-car barriers are not required where platform screens are provided which close off the platform edge and open only when trains are correctly aligned with the doors....
-
11B-809.7.1 Width
Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors....
-
Section H: Lifts
(§§410.5, 309.4) H6 Is the clear width of the door opening/gate opening at the end of the lift at least 32"?...