Where possible, drainage grates should be located outside the minimum clear width of the recreation access route....
Search Results "ALI: Automatic Location Identification"
-
1016.6 Openings
-
1015.1 General
The technical requirements address the clear ground space (1015.2) and viewing space (1015.3) at distinct viewing locations; the turning space within viewing areas (1015.4); and the surface...
-
4.16.2 Clear Floor Space
As a result, toilet room configuration and location of the water closet were the critical design considerations in assisted transfers....
-
4.5.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
What constitutes a “passenger loading zone”?
At other locations, compliance is not required even if passenger loading may occasionally occur, but is not specifically intended or reflected in the design....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
A circle symbol shall be located at entrances to woman’s toilet and bathing facilities. The circle symbol shall be ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter....
-
11B-806.3.2 Notification devices
Telephones shall be served by an electrical outlet complying with Section 11B-309 located within 48 inches (1219 mm) of the telephone to facilitate the use of a TTY....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-703.6.1 Pictogram field
Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field....
-
11B-606.6 Adjacent side wall or partition
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
11B-806.3.2 Notification devices
Telephones shall be served by an electrical outlet complying with Section 11B-309 located within 48 inches (1219 mm) of the telephone to facilitate the use of a TTY....
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
1009.3.2 Submerged Depth
Where landings are required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
5. Safety Hazards
Kirola argues that if the City had adopted and implemented "effective policies for the identification and prompt removal of safety hazards, it is likely that [she] would not have encountered...
-
Requirement to block accessible guest room reservations. (Section-by-Section Analysis)
As described in the discussion on the identification of accessible features in hotels and guest rooms, the presence or absence of particular accessible features may be the difference between...
-
2. Amended TTY Requirements
Guidelines) with 36 CFR 1194.23(c), (e) (2016) (specifying, in original 508 Standards, that telecommunications systems for voice mail, auto-attendant, interactive voice response, and caller identification...
-
11B-806.2.4 Toilet and bathing facilities
Toilet and bathing fixtures required to comply with Sections 11B-603 through 11B-610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between...
-
Integration: ADA Standard Section 221.2.2
Section 221.2.2 covers scoping requirements in the current ADA Standards for integration of wheelchair spaces in assembly areas.
-
Elevated Play Components: ADA Standard Section 240.2.2
Section 240.2.2 covers scoping requirements in the current ADA Standards for elevated play components.
-
11B-1007.2 Accessible routes
Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in Section 11B-1007.2....
-
11B-1007.2 Accessible routes
Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in Section 11B-1007.2....
-
11B-806.2.4 Toilet and bathing facilities
Toilet and bathing fixtures required to comply with Sections 11B-603 through 11B-610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between...