Check plans for Fire Assembly thickness 11B-407.4 Location of controls for operable windows to meet reach range and operation 11B-229 Restroom dimensions....
Search Results "Floor Plan"
Commonly Searched Documents
-
Verify Framing
-
Verify Framing
Check plans for Fire Assembly thickness 11B-407.4 Location of controls for operable windows to meet reach range and operation 11B-229 Restroom dimensions....
-
Managing Question and Answer / Audience Participation
Plan for staff to assist participants who are not able to write on cards....
-
Publicizing the ADA: Advocacy and the Government Response
They planned to use the politics of an election year as a way to publicize the ADA and gain a foothold as a top priority for the next session of Congress....
-
11B-404.2.9 Door and gate opening force
is 35 inches (889 mm) minimum above the floor or ground surface....
-
11B-404.2.9 Door and gate opening force
is 35 inches (889 mm) minimum above the floor or ground surface....
-
E.
Cinemark's auditoria with 300 seats or less, persons who use wheelchairs cannot access the seating on risers as the wheelchair spaces available to them are located on the traditional, sloped-floor...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor. ...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
1.9.1.2
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
902.4 Dining Surfaces and Work Surfaces for Children's Use
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
4.21.6 Shower Unit
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.21.6 SHOWER UNIT
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
11B-203.10 Raised refereeing, judging and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders or other means of reaching the raised elements...
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar, with the opening of the disposal unit 19” minimum (483 mm) above the finish floor....
-
1.9.1.2 Application
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
§ 38.107(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
§ 38.123(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.159(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....