[DSA-AC] A standardized surface feature built in or applied to walking surfaces or other elements to warn persons with visual impairments of hazards on a circulation path....
Search Results "Side Transfer Surface"
-
DETECTABLE WARNING
-
DETECTABLE WARNING
[DSA-AC] A standardized surface feature built in or applied to walking surfaces or other elements to warn persons with visual impairments of hazards on a circulation path....
-
Doors [4.35.3]
Recommendation: For side approaches, maneuvering is easier for a latch-side approach where doors swing out and a hinge-side is often easier where doors swing in....
-
Thresholds: ADA Standard Section 404.2.5
Section 404.2.5 covers the current ADA Standards for thresholds at doors.
-
§27.5 Federal financial assistance
available assistance in the form of: (a) Funds; (b) Services of Federal personnel; or (c) Real or personal property or any interest in, or use of such property, including: (1) Transfers...
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space. ...
-
A4.34.6.7 OVENS
Countertop or wall-mounted ovens with side-opening doors are easier for people in wheelchairs to use....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADA Standards] 805.3 Clear Floor or Ground Space....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
1023.9 Stairway identification signs
braille floor identification signs that comply with Chapter 11A, Section 1143A or Chapter 11B shall be located at the landing of each floor level, placed adjacent to the door on the latch side...
-
1023.9 Stairway identification signs
braille floor identification signs that comply with Chapter 11A, Section 1143A or Chapter 11B shall be located at the landing of each floor level, placed adjacent to the door on the latch side...
-
Taking Measurements
Taking Measurements Sloped Surfaces One way to measure slope is to use a 24-inch level with leveling bubble and a tape measure....
-
Transition Plate
A sloping pedestrian walking surface located at the end(s) of a gangway....
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
Is front-in only or angled parking prohibited for accessible parking spaces?
However, where van spaces are angled, the Standards require the access aisle to be located on the passenger side which is the side where vehicle ramps and lifts are typically deployed....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
Permitted Protrusions in Wheelchair Spaces: ADA Standard Section 1002.4.4.3
protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor or ground surface...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor or ground surface...
-
11B-705.1.2.5 Blended transitions
Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle: "Requirements for detectable warning surfaces...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor or ground surface...