Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
Search Results "Side Transfer Surface"
Commonly Searched Documents
-
Size: ADA Standard Section 604.8.1.1
-
1010.1.6 Thresholds
In occupancy Group R-2 or R-3, threshold heights for sliding and side-hinged exterior doors shall be permitted to be up to 7¾ inches (197 mm) in height if all of the following apply:...
- Zurn Industries 1-1/4" P-Trap and Protectors
- Zurn Industries 1-1/4" x 1-1/2" P-Trap, Offset Strainer, and Protectors
- Zurn Industries 1-1/4" P-Trap, Offset Strainer, and Protectors
- Zurn Industries 1-1/2" P-Trap and Protectors
-
608.8 Shower Enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats. [ECTCR UFAS 4.21.8, 4.34.5.6]...
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
Parking sign height measurement technique
502.6 says "Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign." But which floor or ground surface? ...
-
Appendix D: Photometric Measurements
that would be reflected from a perfectly diffusely reflecting surface....
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings shall extend the full width of the turning space at the demarcation between the street and the sidewalk less 2 inches (sic) (51 mm) maximum on each side....
-
Trail Facilities
not accessible— must be designed to comply with the applicable provisions in FSORAG, except that slopes not steeper than 1:20 (5 percent) are allowed if necessary for drainage of unpaved surfaces...
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors
Doors, and Manual Folding Doors Minimum Maneuvering Clearance Approach Direction Perpendicular to Doorway Parallel to Doorway (beyond stop/latch side...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Minimum Maneuvering Clearance Approach direction Perpendicular to doorway Parallel to doorway (beyond stop/latch side...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
MINIMUM MANEUVERING CLEARANCE Approach direction Perpendicular to doorway Parallel to doorway (beyond stop/latch side...
- Landscape Forms Inc. 35 Sit bench
-
Mirrors: ADA Standard Section 603.3
Section 603.3 covers the current ADA Standards for mirrors in toilet and bathing rooms.
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
11B-705.1.1.1 Dome size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and...
-
B. Door Maneuvering Clearance
Is there adequate room for a person who uses a wheelchair to approach the restroom door from the pull side and pull it open without it hitting the wheelchair - this requires at least 18"...
-
4.17.5* Doors
If toilet stall approach is from the latch side of the stall door, clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in (1065 mm) (Fig. 30...
- AccessRec De-Bug All Terrain Wheelchair
-
30. If an employee is reassigned to a lower level position, must an employer maintain his/her salary from the higher level position?
No, unless the employer transfers employees without disabilities to lower level positions and maintains their original salaries.(91) 91. 29 C.F.R. pt. 1630 app. § 1630.2(o) (1997)....