At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
Search Results "Shall"
-
505.10.3 Bottom Extension at Stairs
-
1014.1 General
Camp shelters shall comply with 1014. EXCEPTIONS: 1....
-
§1193.23(a)
(a) Manufacturers shall evaluate the accessibility, usability, and compatibility of telecommunications equipment and customer premises equipment and shall incorporate such evaluation throughout...
-
11B-303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with Section 11B-303. Exceptions: 1. ...
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
11B-607.5 Controls
Controls, other than drain stoppers, shall be located on an end wall....
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-812.3 Floor or ground surfaces
Vehicle spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle space they serve....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-804.6.2 Operable parts
All appliance controls shall comply with Section 11B-309. Exceptions: Appliance doors and door latching devices shall not be required to comply with Section 11B-309.4....
-
11B-707.7.2 Characters
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I"....
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302....
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
707.7.2 Characters
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I"....
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
VI. TRAINING
Within 60 days after the policies identified in Section V above are approved, WHC shall develop and submit the training curriculum to DOJ for approval, which approval shall not be unreasonably...
-
215 Fire Alarm Systems
Alarms in public use areas and common use areas shall comply with 702....
-
11B-205.1 General
Floor electrical receptacles shall not be required to comply with Section 11B-309. 5. HVAC diffusers shall not be required to comply with Section 11B-309. 6....
-
11B-406.5.3 Landings
Landings shall be provided at the tops of curb ramps and blended transitions. The landing clear length shall be 48 inches (1219 mm) minimum....
-
11B-604.8.1.2 Doors
Where located in the side wall or partition, the door opening shall be farthest from the water closet and shall be 54 inches (1372 mm) minimum from the rear wall. ...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
a single building with one common (lobby) entrance, located on a site with difficult terrain conditions or unusual characteristics: All ground floor units in non-elevator buildings shall...
-
11B-410.1 General
Platform lifts shall comply with ASME A18.1. Platform lifts shall not be attendant-operated and shall provide unassisted entry and exit from the lift....