Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19....
Search Results "Shall"
-
11B-408.3.2.1 Power operation
-
407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
206.1 General
Accessible routes shall be provided in accordance with 206 and shall comply with Chapter 4....
-
219.1 General
Assistive listening systems shall be provided in accordance with 219 and shall comply with 706....
-
705.1 General
Detectable warnings shall consist of a surface of truncated domes and shall comply with 705....
-
ADOPTION AND IMPLEMENTATION OF EFFECTIVE COMMUNICATION POLICY
The heading on the posted Effective Communication Policy shall be printed in capital letters in a bold font no smaller than 26 points....
-
503.4 Floor and Ground Surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the vehicle pull-up space they serve....
-
11B-804.6.2 Operable parts
All appliance controls shall comply with Section 11B-309. Exceptions: 1. ...
-
810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1) and shall have a clear...
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
810.4 Bus Signs
Bus route identification signs shall comply with 703.5.1 through 703.5.4, and 703.5.7 and 703.5.8....
-
407.8.3 Forward Reach
Operable parts of ICT providing a forward reach shall conform to 407.8.3.1 or 407.8.3.2. The vertical reference plane shall be centered, and intersect with, the operable part....
-
711.4.6 Floor fire doors
Floor fire doors used to protect openings in fire-resistance-rated floors shall be tested in the horizontal position in accordance with ASTM E 119, and shall achieve a fire-resistance rating...
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
A4.30.8 Illumination Levels
Illumination levels on the sign surface shall be in the 100 to 300 lux range (10 to 30 footcandles) and shall be uniform over the sign surface....
-
407.12.3 Forward Reach
Operable parts of ICT providing a forward reach shall conform to 407.12.3.1 or 407.12.3.2. The vertical reference plane shall be centered, and intersect with, the operable part....
-
R409.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beyond the top and bottom of ramp runs....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-804.6.2 Operable parts
All appliance controls shall comply with Section 11B-309. Exceptions: 1. Appliance doors and door latching devices shall not be required to comply with Section 11B-309.4. 2....
-
11B-503.4 Floor and ground surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle pull-up space they serve....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....