Overlapping Fixed Elements Fixed elements can overlap turning space if required knee and toe clearances are provided....
Search Results "Maneuvering Clearance (Alcove)"
-
Wheelchair Turning Space [4.2.3]
-
T303.4 Clearance
Clearance between gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
Plan 3A: 12-Foot Wide Accessible Guest Room
(section 604.2); and • No other fixtures or obstructions located within required water closet clearance (section 604.3). ...
-
Plan 1A: 13-Foot Wide Accessible Guest Room
(section 604.2); and • No other fixtures or obstructions located within required water closet clearance (section 604.3). ...
-
Plan 1B: 13-Foot Wide Accessible Guest Room
at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall...
-
11B-804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524...
-
11B-804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524...
-
Revised Knee Clearance Depth and Footrest Clearance dimensions for sizing of mammography equipment
Access Board RE: Revised Knee Clearance Depth and Footrest Clearance dimensions for sizing of mammography equipment...
-
Pass Through Kitchen: ADA Standard Section 804.2.1
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
17.1 Q. Is it correct that only the exterior side of the main entry door of covered multifamily dwellings must meet the ANSI requirements?
These specifications include necessary maneuvering clearances and accessible door hardware....
-
11B-306.3 Knee clearance
[See subsections ...]
-
11B-306.2 Toe clearance
[See subsections ...]
-
11B-306.2 Toe clearance
[See subsections ...]
-
11B-306.3 Knee clearance
[See subsections ...]
-
11B-306.3 Knee clearance
[See subsections ...]
-
11B-306.2 Toe clearance
[See subsections ...]
-
11B-305.4 Knee and toe clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-305.4 Knee and toe clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-305.4 Knee and toe clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
R404.7.1 Forward Approach
The clear space and additional maneuvering space shall be 915 mm (3.0 ft) wide minimum where the depth exceeds 610 mm (2.0 ft)....
-
R404.7.2 Parallel Approach
The clear space and additional maneuvering space shall be 1525 mm (5.0 ft) wide minimum where the depth exceeds 380 mm (1.25 ft)....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering...