The height of the top of the gripping surface on horizontal standing supports shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum above the standing surface.
Search Results "Braille Position"
Commonly Searched Documents
-
M305.3.2.1 Horizontal Position
-
5.9.1 Standing Supports In Reference To Mammography Equipment
To be useful, positioning supports must be shaped for grasping, positioned within reach range of all users, and be 12 inches long minimum when located on the moving C-arm or 18 inches long...
-
5.1 Transfer Surface Height
5.1 Transfer Surface Height
-
5.1.4 Transfer Surface Height Measurement
5.1.4 Transfer Surface Height Measurement. The transfer surface height should be measured from the floor to the highest point on the seat in an uncompressed state, inclusive of...
- Seton ADA Braille Sign - Emergency Exit Only 89424
-
M305.2.2 Length
The length of transfer supports shall comply with M305.2.2.1 or M305.2.2.2.
-
5.5.1 Armrest Provision for M302
5.5.1 Armrest Provision for M302 Description: Diagnostic equipment used by patients in a seated position such as exam chairs typically have armrests....
- 703.4.1 Raised Letter and Braille Signage Height
-
Armrests (M302.3.2)
M302.3.2 would require armrests to be provided on diagnostic equipment used by patients in a seated position....
-
Identification [4.3.11.5]
Requirements for tactile (raised and Braille) signage apply to exits and other designations of "permanent rooms and spaces."...
- Innerface ARQ Interior Sign Frame System
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer.
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum.
-
M305.2.7 Clearance (Section-by-Section Analysis)
In the MDE NPRM, the Access Board did not provide any specific requirements for clearances around the transfer support. However, in the preamble to the MDE NPRM the Access Board...
-
M305.2.3 Fittings
Transfer supports shall not rotate within their fittings.
- Innerface Clearview Interior Signage
-
Examples of Alternative Formats
If an individual requests a specific point size, provide notice in that size) Braille Text file on a thumb disk or emailed to the person HTML format on an accessible...
-
5.2.1.1 Transfer Surface Width Recommendations for M301
Transfer Surface Width Recommendations for M301 The Committee recommends a transfer surface of 28 inches minimum width for equipment used by patients in a supine, side-lying, or prone position...
-
M302.2.2 Sunset
The low transfer position height, Item A of M302.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register]. [sic]...
-
2. Written Communications
Alternative formats such as Braille, large print text, emails or compact discs (CDs) with the information in accessible formats, or audio recordings are often effective ways of making information...
-
M305.3.1.3 Vertical Position
The length of the gripping surface on vertical standing supports shall be 18 inches (455 mm) minimum.
-
M305.3.2.2 Vertical Position
The height of the lowest end of the gripping surface on vertical standing supports shall be 34 inches (865 mm) minimum and 37 inches (940 mm) maximum above the standing surface.
-
M305.3.2 Vertical Position
Where the support is vertical, it shall be 18 inches (455 mm) minimum in length and the bottom end of the support shall be 34 inches (865 mm) high minimum and 37 inches (940 mm) high...
-
c. Transfer Surface Size for Diagnostic Equipment Used by Patients in the Supine, Prone, or Side-lying Position
The MDE NPRM proposed a transfer surface size for diagnostic equipment used in the supine, prone, or side-lying position of 30 inches wide and 15 inches deep minimum (proposed M301.2.2)....