Swing bays that provide an accessible route, clear floor or ground space, maneuvering space, and the seat at a height between 11 to 24 inches to more than one swing, can count each swing...
Search Results "Floor Identification"
Commonly Searched Documents
-
6. Where multiple swings in a swing bay are provided, Section 240.2.1.1 (one of each type) requires one swing to be located on an accessible route. If an accessible route is provided to more than one swing, can each swing be counted as an accessible ground level play component? If one is an infant seat and another a sling seat, are those considered two different types?
-
Accessible Routes
Clear floor space required at play components and maneuvering space can overlap the accessible route. ...
-
809.2 Residential Dwelling Units with Mobility Features
809.2 Residential Dwelling Units with Mobility Features As discussed below, the final rule adds technical requirements to this section for floor surfaces, bedrooms, and weather alert...
-
1008.2.3 Water Play Components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
Why are surface characteristics specified?
Findings from this limited human-subject testing confirmed that individuals who have gait and mobility disabilities make greater demands on the walking surfaces of floors, ramps, and walkways...
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
Addendum G: Comparison of Transfer Abilities between Men and Women
The average wheelchair seat to floor height for men was 22.2 (±1.44) inches and the average height for women was 21.65 (±1.31) inches....
-
A. Signs
If signs are provided for the following spaces, are the signs mounted on the wall (not the door) to the latch side of the door and centered 60" above the floor so that they can be easily...
-
1008.2.3 Water Play Components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
Section 2. Definitions
New terms defined in the final Guidelines include: "adaptable," "assistive device," "ground floor," "loft," "multistory dwelling unit," "single-story dwelling unit," and "story"....
-
C. Accessibility Within Toilet Rooms
Is at least one stall at least 60 inches wide and 56 inches deep (wall mounted toilet) or 59 inches deep (floor mounted toilet)?...
-
610.3 Shower Compartment Seats
The top of the seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. Seats shall comply with 610.3.1 or 610.3.2. ...
-
407.12.2.1 Unobstructed Side Reach (Section-by-Section Analysis)
proposes that, where the operable part is located 10 inches or less behind the vertical reference plane, the operable part must be 48 inches high maximum and 15 inches high minimum above the floor...
-
What access do I need?
◼ I need an exam table that lowers to 17–19 inches from the floor. ◼ I need help getting on and off the exam table. ◼ I need to bring my service dog....
-
Tactile and Visual Signs [ADA Standards §216.2, §216.4.1]
This requirement applies to signs identifying stairways, floor levels, and areas of refuge. Examples of Signs Required to Meet Tactile and Visual Criteria...
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
- Elkay Cane Apron LKAPREZL for use with EZ Bi-Level Drinking Fountains
- American Specialties 9018 Recess Mounted Stainless Steel Horizontal Baby Changing Station
- Nana Wall Systems, Inc. Folding Glass Walls SL60
- BraunAbility Millenium 2 Wheelchair Lift for School Buses, Cutaway Buses, and Paratransit Vans
-
PATH OF TRAVEL
(A) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
11B-224.8.2 More than 50-bed facilities
In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
-
11B-205.1 General
Floor electrical receptacles shall not be required to comply with Section 11B-309. 5. HVAC diffusers shall not be required to comply with Section 11B-309. 6....