(8) Platform edges bordering a drop-off and not protected by platform screens or guard rails shall have a detectable warning....
Search Results "Shall"
-
10.3.1(8)
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
502.3.4 Location
Access aisles shall not overlap the vehicular way....
-
4.28.4* AUXILIARY ALARMS
Accessible sleeping accommodations shall have a visual alarm connected to the building emergency alarm system or shall have a standard 110-volt electrical receptacle into which such an alarm...
-
7.3 CHECK-OUT AISLES
At least one accessible check-out aisle shall be provided in buildings or facilities with check-out aisles....
-
11B-810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 and shall have a clear width of 32 inches (813 mm) minimum....
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
1009.6 Areas of refuge
Every required area of refuge shall be accessible from the space it serves by an accessible means of egress....
-
11B-206.7 Platform lifts
Platform lifts shall comply with Section 11B-410. Platform lifts shall be permitted as a component of an accessible route in new construction in accordance with Section 11B-206.7....
-
11B-810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 and shall have a clear width of 32 inches (813 mm) minimum....
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-206.7 Platform lifts
Platform lifts shall comply with Section 11B-410. Platform lifts shall be permitted as a component of an accessible route in new construction in accordance with Section 11B-206.7....
-
1009.6 Areas of refuge
Every required area of refuge shall be accessible from the space it serves by an accessible means of egress....
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2....
-
M302.2 Transfer Surface
A transfer surface shall be provided and shall comply with M302.2....
-
M302.2 Transfer Surface
A transfer surface shall be provided and shall comply with M302.2....
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2....
-
11B-809.9 Kitchens
Kitchens shall be on an accessible route and shall comply with this section....
-
11B-223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...
-
11B-410.1 General
Platform lifts shall comply with ASME A18.1. Platform lifts shall not be attendant-operated and shall provide unassisted entry and exit from the lift....
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
a single building with one common (lobby) entrance, located on a site with difficult terrain conditions or unusual characteristics: All ground floor units in non-elevator buildings shall...
-
11B-223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...
-
11B-410.1 General
Platform lifts shall comply with ASME A18.1. Platform lifts shall not be attendant-operated and shall provide unassisted entry and exit from the lift....
-
Marking: ADA Standard Section 502.3.3