Floor destination characters shall be displayed upon elevator car arrival at the input floor and shall not extinguish until the elevator car arrives at the destination floor....
Search Results "Shall"
Commonly Searched Documents
-
11B-411.4.11.3 Duration
-
11B-206.4.6 Residential dwelling unit primary entrance
In residential dwelling units, at least one primary entrance shall comply with Section 11B-404. The primary entrance to a residential dwelling unit shall not be to a bedroom....
-
11B-1008.3.1 Transfer platforms
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with Section 11B-1008.3.1....
-
11B-812.6.4 Drive-up
Vehicle spaces serving drive-up EVCS shall be 204 inches (5182 mm) wide minimum and shall not be required to have an adjacent access aisle....
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
11B-608.6 Shower spray unit and water
The shower spray unit shall have an on/off control with a non-positive shut-off....
-
207 Accessible Means of Egress
Areas of rescue assistance shall comply with 4.3.11....
-
2.1 General
ORARs shall be provided between units and constructed features in campgrounds, picnic areas, trailheads, viewing areas, and other outdoor recreation sites....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
1134A.5, Item 1
There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to provide for the maneuvering...
-
610.3.2 L-Shaped Seats
The rear edge of an L-shaped seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall....
-
406.6 Diagonal Curb Ramps
Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow....
-
406.7 Islands
Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides....
-
1003.2.2 Boarding Piers at Boat Launch Ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in 1003.2.2. EXCEPTIONS: 1....
-
607.6 Shower Spray Unit and Water
The shower spray unit shall have an on/off control with a non-positive shut-off....
-
1003.2.2 Boarding Piers at Boat Launch Ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in 1003.2.2. EXCEPTIONS: 1....
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
11B-607.6 Shower spray unit and water
The shower spray unit shall have an on/off control with a non-positive shut-off....
-
302.1 General
Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 302. EXCEPTIONS: 1....
-
4.1.3(9)*
(9)* In buildings or facilities, or portions of buildings or facilities, required to be accessible, accessible means of egress shall be provided in the same number as required for exits...
-
4.13.9* DOOR HARDWARE
Handles, pulls, latches, locks, and other operating devices on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, tight pinching...
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
4.7.10 DIAGONAL CURB RAMPS
If diagonal (or corner type) curb ramps have returned curbs or other well-defined edges, such edges shall be parallel to the direction of pedestrian flow....