Operable parts shall comply with Section 11B-309....
Search Results "Shall"
-
11B-707.3 Operable parts
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
504.5 Nosings
The radius of curvature at the leading edge of the tread shall be ½ inch (13 mm) maximum....
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location. ...
-
407.2.3.1 Floor Designation
Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
608.3.2 Standard Roll-In Type Shower Compartments
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat....
-
R310.3 Access Aisle
Passenger loading zones shall provide access aisles complying with R310.3 adjacent to the vehicle pull-up space....
-
504.5 Nosings
The radius of curvature at the leading edge of the tread shall be 1/2 inch (13 mm) maximum....
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
10.4.1(5)
(5) Baggage check-in and retrieval systems shall be on an accessible route complying with 4.3, and shall have space immediately adjacent complying with 4.2.4....
-
9.5.3 Accessible Sleeping Accommodations in New Construction
Accessible sleeping rooms shall be provided in conformance with the table in 9.1.2 and shall comply with 9.2 Accessible Units, Sleeping Rooms and Suites (where the items are provided)....
-
4.1.3(11) Toilet Facilities
(11) Toilet Facilities: If toilet rooms are provided, then each public and common use toilet room shall comply with 4.22....
-
4.1.3(17)(b)
(b)* All telephones required to be accessible and complying with 4.31.2 through 4.31.8 shall be equipped with a volume control....
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location....
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
707.5.1 User Control
Speech shall be capable of being repeated or interrupted. Volume control shall be provided for the speech function....
-
11B-406.5.6 Grade breaks
Grade breaks at the top and bottom of curb ramp runs shall be perpendicular to the direction of the ramp run....
-
809.1 General
Residential dwelling units shall comply with 809. Residential dwelling units required to provide mobility features shall comply with 809.2 through 809.4....
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
4.13.2 Revolving Doors and Turnstiles
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
-
4.34.5.5(3) Grab bars
Structural reinforcement or other provisions that will allow installation of grab bars shall be provided in the locations shown in Fig. 49....
-
502.4 Floor or Ground Surfaces
Parking spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted....
-
4.13.2 REVOLVING DOORS AND TURNSTILES
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
-
4.34.5.5(4) Controls
Faucets and other controls shall be located as shown in Fig. 37 and shall comply with 4.27.4....